文献速递乳房整形与再造

组织扩张器乳房再造改良评估:一家私立诊所内的质量改进评估

Evaluation of Modifications to Tissue-Expander Breast Reconstruction, a Quality Improvement Assessment Within a Private Practice.
PubMed 文献 · Ann Plast Surg · 2018-01-01

作者回顾性比较早期组织扩张器乳房再造病例与前瞻性开展的采用免触碰操作及柔软穿孔脱细胞真皮基质(ADM)的当前病例。共分析53例患者(87侧乳房),早期组29例使用早期ADM,当前组24例采用免触碰操作和柔软穿孔ADM。结果显示当前组引流管留置天数显著更少,BREAST-Q评分显著改善(P < 0.005),作者认为免触碰技术和功能特性有利的ADM似乎改善了患者结局。

要点

  • 当前组采用免触碰操作和柔软穿孔ADM,引流管留置天数显著少于早期组。
  • 当前组患者报告BREAST-Q评分显著改善(P < 0.005),满意度高。
  • 早期组发生3例再造失败,当前组未报告再造失败。

核心结论

  • 使用免触碰技术和一种设计上具有利于乳房再造手术功能特性的ADM,似乎改善了患者结局。

研究设计与样本

  • 回顾性比较作者早期经验中实施的一系列组织扩张器再造与前瞻性实施的相似数量病例,评估人口学、围手术期特征和术后结局。
  • 共分析53例患者(87侧乳房),其中早期组29例使用当时可用的早期ADM之一,当前组24例采用免触碰操作和柔软穿孔ADM。

主要发现

  • 两队列人口学和围手术期特征相当,平均年龄47.6岁,BMI为25.8,18.9%有当前或既往尼古丁使用。
  • 即刻再造在75侧(86.2%)乳房中实施,引流管留置时间为16 ± 8.9天,后组所需天数显著更少。
  • 平均随访9.6个月,并发症包括早期包膜增厚7例(13.2%)需在二期交换手术时行包膜切除术,假体(扩张器)取出3侧(3.4%)乳房,需干预的显著感染3例(5.7%),血清肿3例(5.7%),伤口裂开2例(3.8%),皮瓣坏死和血肿各1例(1.9%)。
  • ADM融合不全见于9侧(10.3%)乳房,早期队列发生3例再造失败。
  • 后组患者报告术后BREAST-Q评分显著改善(P < 0.005),满意度高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: As technology advances, surgical practice evolves over time. The author assesses a new approach to implant-based breast reconstruction and the impact of two changes implemented over several years. METHODS: A series of tissue-expander reconstructions performed early in the author's experience were retrospectively compared with a similar number of cases prospectively performed. Demographics, perioperative characteristics, and postoperative outcomes were assessed. RESULTS: Fifty-three patients (87 breasts) were analyzed, 29 treated earlier with one of the early acellular dermal matrices (ADMs) available and 24 current cases using a no-touch operative approach and pliable, perforated ADM. Demographics and perioperative characteristics between the cohorts were comparable. Mean age was 47.6 years, body mass index (BMI) of 25.8 and 18.9% had current or former nicotine use. Immediate reconstruction was performed in 75 (86.2%) breasts. Drains remained in situ 16 ± 8.9 days, with a significantly lower number of days required in latter patients. At a mean follow-up of 9.6 months, complications included early capsular thickening in 7 (13.2%) patients requiring capsulectomy at the second stage exchange surgery, prosthetic (expander) removal in 3 (3.4%) breasts, significant infection requiring intervention in 3 (5.7%) patients, seroma in 3 (5.7%) patients, 2 (3.8%) cases of wound dehiscence, and 1 (1.9%) case of flap necrosis and hematoma. Incomplete ADM incorporation was observed in 9 (10.3%) breasts. Three reconstructive failures occurred in the early cohort. Patients in the later cohort reported significantly improved BREAST-Q scores (P < 0.005) postoperatively with a high level of satisfaction. CONCLUSIONS: Using a no-touch technique and an ADM designed with functional characteristics advantageous to breast reconstructive surgery appears to have improved patient outcomes.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Wilson H, Varnadore A. Evaluation of Modifications to Tissue-Expander Breast Reconstruction, a Quality Improvement Assessment Within a Private Practice. Ann Plast Surg. 2018. PMID: 29389701. doi:10.1097/SAP.0000000000001320

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。