基于微型CT的密度分析用于研究烧冲复合伤相关肺损伤
研究建立爆炸伤组、烧伤组、烧冲复合伤组和假手术对照组,每组16只大鼠,于伤后6、24、48小时行CT三维重建计算全肺、左肺、右肺平均密度,并行HE染色和Smith评分。烧冲复合伤组肺组织密度高于爆炸伤组和烧伤组(P<0.01),伤后24小时肺组织密度值高于伤后6小时和48小时(P<0.01),病理结果证实了密度分析的变化。结果表明CT密度分析可用于评估烧冲复合伤中的肺损伤。
要点
- 烧冲复合伤组肺组织密度高于爆炸伤组和烧伤组(P<0.01)。
- 伤后24小时肺组织密度值高于伤后6小时和48小时(P<0.01)。
- 病理结果证实了肺组织密度分析的变化。
核心结论
- 结果表明,通过CT扫描进行密度分析可作为评估烧冲复合伤中肺损伤的一种方法。
研究设计与样本
- 建立爆炸伤组(BL组)、烧伤组(B组)、烧冲复合伤组(BBL组)和假手术对照组(C组),每组16只大鼠。
- 采用快速三维重建方法,根据CT值于伤后6小时、24小时、48小时获取肺组织三维图像,测量全肺、左肺和右肺平均密度。
- 肺组织行石蜡包埋和HE染色,根据病理所见进行Smith评分。
主要发现
- 烧冲复合伤组肺组织密度高于爆炸伤组和烧伤组(P<0.01)。
- 伤后24小时肺组织密度值高于伤后6小时和48小时(P<0.01)。
- 病理结果证实了肺组织密度分析的变化。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Burn-blast combined injury is a kind of injury caused by heat and blast at the same time. The lung injury after burn-blast combined injuries is of primary importance, and investigation of lung injury is needed in the clinical care of patients. Computed tomography (CT) is one of the standard tools used to observe the anatomical basis and pathophysiology of acute lung injury. METHODS: We applied a method of fast 3D (three-dimensional) reconstruction to calculate the density value of the lung injury by CT analysis. Blast-injury group (BL group), burn-injury group (B group), burn-blast combined injury group (BBL group), and sham control group (C group) were established. Each group had 16 rats. The three-dimensional images of the lung tissue were obtained at 6h, 24h, and 48h according to the CT value. The average density of the whole lung, left lung, and right lung were measured. The lung tissues were paraffin-embedded and HE stained. Smith scoring was performed according to the pathological findings. RESULTS: In the BBL group, the density of the lung tissue was higher than those of the BL group and B group (P<0.01). The lung tissue density values at 24h after injury were higher than those at 6h and 48h after injury (P<0.01). Pathological results confirmed the changes of density analysis of the lung tissue. CONCLUSION: The results have indicated that density analysis through a CT scan can be used as a way to evaluate lung injury in a burn-blast injury.
引用
- Chang Y, Zhang DH, Hu Q, et al. Usage of density analysis based on micro-CT for studying lung injury associated with burn-blast combined injury. Burns. 2018. PMID: 29449035. doi:10.1016/j.burns.2017.12.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。