减重后臂部整形术采用后内侧瘢痕:物理模型、技术改良与临床结局
研究建立手臂物理模型比较后内侧与内侧瘢痕的力学应力,并报告24例减重后患者行后内侧瘢痕臂部整形术联合脂肪抽吸、筋膜折叠和腋窝Z成形术的临床结局;模型显示后内侧瘢痕应力与位移更小,23例愈合顺利,1例(4.1%)发生2 cm裂开,瘢痕评估与患者主观满意度均较好。
要点
- 物理模型显示后内侧瘢痕承受的机械应力与位移均小于内侧瘢痕。
- 24例中23例愈合顺利,1例(4.1%)出现2 cm裂开。
- 患者与观察者瘢痕评估量表均分分别为2±0.76和2.13±0.64。
核心结论
- 物理模型证明后内侧瘢痕所受机械应力与位移更低,所报告的技术改良可实现外观良好的手臂再塑形,瘢痕可接受且并发症发生率低。
研究设计与样本
- 24例减重后患者接受后内侧瘢痕臂部整形术,同期行脂肪抽吸、筋膜折叠和腋窝Z成形术。
- 对皮肤标本进行测试并建立手臂物理模型,研究后内侧与内侧瘢痕机械应力的差异。
- 使用经验证的患者与观察者瘢痕评估量表、温哥华瘢痕量表及主观改善问卷进行评估,术前术后照片由三名独立整形外科医生评定。
- 证据等级为治疗性,IV级。
主要发现
- 物理模型显示后内侧位置的瘢痕应力强度和分布均降低,加载模拟中瘢痕位移更小。
- 23例愈合顺利,1例(4.1%)发生2 cm裂开。
- 患者与观察者瘢痕评估量表均分分别为2±0.76和2.13±0.64。
- 温哥华瘢痕量表均值为3.5±1.7。
- 主观结局问卷均值为3.45±0.63(满分4分),医生评估得分为4.5±0.4(满分5分)。
临床怎么用
- 作者报告的技术改良包括后内侧瘢痕放置、同期脂肪抽吸、筋膜折叠和腋窝Z成形术,作者认为可实现外观良好的手臂再塑形、瘢痕可接受且并发症发生率低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Brachioplasty is an increasingly performed procedure following massive weight loss. A visible scar is the main hindrance to this surgery. The aims of the study were to develop a physical model to investigate the ideal location of the surgical incision and to present the authors' technical refinements with the posteromedial scar approach. METHODS: Twenty-four postbariatric patients underwent brachioplasty with posteromedial scar placement, concomitant liposuction, fascial plication, and axillary Z-plasty. Skin specimens were tested and a physical model of the arm was set up to investigate the difference in mechanical stress on the posteromedial and medial scars. The validated Patient and Observer Scar Assessment Scale, the Vancouver Scar Scale, and a questionnaire assessing subjective improvements were administered to patients. Preoperative and postoperative photographs were assessed by three independent plastic surgeons. RESULTS: The physical model showed that stress intensity and distribution along the scar were reduced in the posteromedial location, with smaller scar displacement in the loading simulations. Twenty-three patients healed uneventfully. One (4.1 percent) had a 2-cm dehiscence. Mean Patient and Observer Scar Assessment Scale scores were, respectively, 2 ± 0.76 and 2.13 ± 0.64 in the patients' and observers' questionnaires. The mean Vancouver Scar Scale value was 3.5 ± 1.7. Questionnaires assessing the subjective outcomes showed a mean value of 3.45 ± 0.63 of 4. The surgeons' assessment resulted in a score of 4.5 ± 0.4 of 5. CONCLUSIONS: The physical model demonstrated that the posteromedial scar was subjected to lower mechanical stress and displacement. The reported technical refinements allowed pleasant arm recontouring to be achieved with acceptable scarring and a low incidence of complications. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Simone P, Carusi C, Segreto F, et al. Postbariatric Brachioplasty with Posteromedial Scar: Physical Model, Technical Refinements, and Clinical Outcomes. Plast Reconstr Surg. 2018. PMID: 29369986. doi:10.1097/PRS.0000000000004060
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。