穿支血管定位可缩短DIEP皮瓣乳房再造手术时间:术前超声、计算机断层扫描血管成像与磁共振血管成像的系统综述与Meta分析
该系统综述与Meta分析纳入14篇文章,比较术前超声、CTA或MRA穿支血管定位与不定位对DIEP皮瓣乳房再造手术时间及不良结局的影响。CTA或MRA定位较不定位显著缩短手术时间(平均减少54分钟,95%CI 3–105,p=0.04);CTA优于超声,平均节省58分钟(95%CI 25–91,p<0.001),且部分皮瓣失败风险更低(RR 0.15,95%CI 0.04–0.6,p=0.007)。所有研究存在方法学偏倚风险,证据质量极低。
要点
- CTA或MRA穿支定位较不定位平均缩短手术时间54分钟(95%CI 3–105,p=0.04)。
- CTA较超声平均节省手术时间58分钟(95%CI 25–91,p<0.001)。
- CTA与部分皮瓣失败风险更低相关(RR 0.15,95%CI 0.04–0.6,p=0.007)。
核心结论
- 关于DIEP皮瓣乳房再造术前穿支定位的研究质量差,术前血管成像似乎可节省手术时间、降低并发症并节省费用,但需要更高质量的研究。
研究设计与样本
- 系统综述与Meta分析,系统检索文献纳入14篇直接比较成人女性DIEP皮瓣乳房再造术前有无超声、CTA或MRA穿支定位的手术时间与不良结局的研究。
- PROSPERO注册号CRD42017065012。
主要发现
- 与不进行穿支定位相比,CTA或MRA术前穿支定位显著缩短手术时间(平均减少54分钟,95%CI 3–105,p=0.04)。
- CTA定位优于超声定位,CTA节省更多手术室时间(平均减少58分钟,95%CI 25–91,p<0.001)。
- CTA定位与部分皮瓣失败风险更低相关(RR 0.15,95%CI 0.04–0.6,p=0.007)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 所有研究均存在方法学偏倚风险。
- 证据质量极低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prior to DIEP flap breast reconstruction, mapping the perforators of the lower abdominal wall using ultrasound, computed tomography angiography (CTA) or magnetic resonance angiography (MRA) reduces the risk of flap failure. This review aimed to investigate the additional potential benefit of a reduction in operating time. METHODS: We systematically searched the literature for studies concerning adult women undergoing DIEP flap breast reconstruction, which directly compared the operating times and adverse outcomes for those with and without preoperative perforator mapping by ultrasound, CTA or MRA. Outcomes were extracted, data meta-analysed and the quality of the evidence appraised. RESULTS: Fourteen articles were included. Preoperative perforator mapping by CTA or MRA significantly reduced operating time (mean reduction of 54 minutes [95% CI 3, 105], p = 0.04), when directly compared to DIEP flap breast reconstruction with no perforator mapping. Further, perforator mapping by CTA was superior to ultrasound, as CTA saved more time in theatre (mean reduction of 58 minutes [95% CI 25, 91], p < 0.001) and was associated with a lower risk of partial flap failure (RR 0.15 [95% CI 0.04, 0.6], p = 0.007). All studies were at risk of methodological bias and the quality of the evidence was very low. CONCLUSIONS: The quality of research regarding perforator mapping prior to DIEP flap breast reconstruction is poor and although preoperative angiography appears to save operative time, reduce morbidity and confer cost savings, higher quality research is needed. REGISTRATION: PROSPERO ID CRD42017065012.
引用
- Wade RG, Watford J, Wormald JCR, et al. Perforator mapping reduces the operative time of DIEP flap breast reconstruction: A systematic review and meta-analysis of preoperative ultrasound, computed tomography and magnetic resonance angiography. J Plast Reconstr Aesthet Surg. 2017. PMID: 29289500. doi:10.1016/j.bjps.2017.12.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。