文献速递乳房整形与再造美容整形

Poly Implants Prosthèse乳房假体:病例系列研究及文献综述

Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.
PubMed 文献 · Ann Plast Surg · 2018-01-01

本研究纳入2011年1月至2017年1月在以色列接受择期乳房假体置换的73例乳房隆乳女性患者,共146枚Poly Implants Prosthèse(PIP)乳房假体,平均假体年龄6.7±2.79年,平均假体体积342.8±52.9 mL,14例女性(19枚假体[16%])存在高级别包膜挛缩(Baker 3-4级),置换术中28枚假体(19.2%)发现破裂。作者结论认为PIP假体在隆乳后不到10年即表现出较其他假体更高的破裂率,对于明确破裂诊断的患者应推荐择期取出假体。

要点

  • 73例女性共146枚PIP假体,平均假体年龄6.7±2.79年,平均体积342.8±52.9 mL。
  • 14例女性(19枚假体[16%])存在Baker 3-4级高级别包膜挛缩。
  • 置换术中28枚假体(19.2%)发现破裂,作者认为PIP假体破裂率高于其他假体。

核心结论

  • 隆乳后不到10年,PIP假体表现出较其他假体更高的破裂率,本研究数据与目前可获得的总体破裂率相当。
  • 对于明确破裂诊断的患者,应推荐择期取出假体。
  • 对于未受损的假体,整形外科医生也应认真考虑取出PIP假体。
  • 当患者不希望取出假体时,建议从隆乳后一年开始每年进行体格检查和乳房超声检查。

研究设计与样本

  • 病例系列研究及文献综述,纳入2011年1月至2017年1月在以色列接受择期乳房假体置换的乳房隆乳患者,数据来自电子和纸质医疗档案。
  • 共纳入73例乳房隆乳女性患者、146枚PIP乳房假体。

主要发现

  • 平均假体年龄6.7±2.79年,平均假体体积342.8±52.9 mL。
  • 14例女性(19枚假体[16%])存在高级别包膜挛缩(Baker 3-4级)。
  • 置换术中28枚假体(19.2%)发现破裂。

关键数值与推荐

  • 2011年12月,法国卫生部建议考虑取出PIP假体,无论其状况如何。
  • 2012年,以色列卫生部建议仅在怀疑假体破裂时更换假体。
  • 本研究中高级别包膜挛缩定义为Baker 3-4级,见于14例女性(19枚假体[16%])。
  • 本研究中置换术中假体破裂率为19.2%(28枚假体)。

临床怎么用

  • 对于明确破裂诊断的患者,作者建议应推荐择期取出假体。
  • 对于未受损的假体,作者认为整形外科医生也应认真考虑取出PIP假体。
  • 当患者不希望取出假体时,作者建议从隆乳后一年开始每年进行体格检查和乳房超声检查。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. OBJECTIVES: The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. METHODS: Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. RESULTS: There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). CONCLUSIONS: Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Klein D, Hadad E, Wiser I, et al. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature. Ann Plast Surg. 2018. PMID: 29166315. doi:10.1097/SAP.0000000000001294

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。