近红外光谱技术在皮瓣监测中的应用系统综述:当前基础与临床证据及前景

A systematic review of near-infrared spectroscopy in flap monitoring: Current basic and clinical evidence and prospects.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2017-11-22

该综述检索PubMed与Web of Science至2016年12月31日,纳入15项临床研究和8项动物研究,总结近红外光谱(NIRS)用于皮瓣监测的证据。当以每2小时或更短间隔测量StO2时,总皮瓣成功率为99.5%,皮瓣挽救率为91.1%。单用StO2监测检测血管问题的敏感性为99.1%、特异性为99.9%,且早于其他监测方法,但额外监测Hb浓度有助于避免假阴性并区分动脉与静脉闭塞。结论认为NIRS可用于皮瓣监测并在多种情况下显示高准确性,但需进一步研究以充分发挥其潜力。

要点

  • 每2小时或更短间隔测量StO2时,总皮瓣成功率99.5%,皮瓣挽救率91.1%。
  • 单用StO2监测检测血管问题的敏感性99.1%、特异性99.9%,且早于其他监测方法。
  • 额外监测Hb浓度有助于避免假阴性并区分动脉与静脉闭塞。

核心结论

  • NIRS可用于皮瓣监测并在多种情况下显示高准确性,但需进一步研究以充分发挥NIRS的潜力。

研究设计与样本

  • 系统综述,检索PubMed和Web of Science数据库,检索词为「flap monitoring AND near-infrared spectroscopy」和「flap monitoring AND tissue oxygen saturation」,研究时段从建库至2016年12月31日。
  • 由两名作者独立提取文章并评估研究质量,纳入与NIRS皮瓣灌注监测相关的文章而不限研究类型。
  • 共纳入15项临床研究和8项动物研究。

主要发现

  • 当以每2小时或更短间隔测量StO2时,总皮瓣成功率为99.5%,皮瓣挽救率为91.1%。
  • 单用StO2监测检测血管问题的敏感性为99.1%、特异性为99.9%,且早于其他监测方法。
  • 额外监测Hb浓度有助于避免假阴性并区分动脉与静脉闭塞。

关键数值与推荐

  • 当以每2小时或更短间隔测量StO2时,总皮瓣成功率为99.5%,皮瓣挽救率为91.1%。
  • 单用StO2监测检测血管问题的敏感性为99.1%、特异性为99.9%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Near-infrared spectroscopy (NIRS) has been reported to be a reliable non-invasive modality for free flap monitoring; however, the history of its application in flap monitoring is short, and there is no definite consensus regarding its use at present. OBJECTIVES: The aim of this review is to clarify the evidence related to post-operative flap monitoring using NIRS and examine its appropriateness and usability. MATERIALS AND METHODS: The PubMed and Web of Science databases were searched using the strings "flap monitoring AND near-infrared spectroscopy" and "flap monitoring AND tissue oxygen saturation," with a study period from inception to December 31, 2016. Two authors independently extracted articles and assessed the quality of the studies. Articles related to NIRS for flap perfusion monitoring were classified and selected regardless of study type. RESULTS: A total of 15 clinical studies and 8 animal studies were identified and reviewed. The evidence and information on various aspects of NIRS flap monitoring were summarized. The overall flap success rate was 99.5%, and the flap salvage rate was 91.1%, when measuring StO2 at intervals of every 2 h or sooner. Single StO2 monitoring was able to detect vascular compromise with 99.1% sensitivity and 99.9% specificity, and earlier than other monitoring methods, but additional Hb concentration monitoring was useful for avoiding false negatives and differentiating arterial and venous occlusion. CONCLUSIONS: NIRS can be used for flap monitoring and displays high accuracy in various situations; however, further studies are needed to take full advantage of the potential of NIRS.