文献速递乳房整形与再造显微修复重建

腹壁皮瓣乳房再造术后并发症与患者报告结局:乳房切除再造结局联盟研究结果

Complications and Patient-Reported Outcomes after Abdominally Based Breast Reconstruction: Results of the Mastectomy Reconstruction Outcomes Consortium Study.
PubMed 文献 · Plast Reconstr Surg · 2018-01-01

该前瞻性多中心研究纳入11个中心接受腹壁皮瓣乳房再造的患者,比较带蒂TRAM、游离TRAM、DIEP和SIEA皮瓣的并发症与患者报告结局。720例完成1年随访、587例完成2年随访。2年时SIEA较DIEP供区并发症发生率更高(OR 2.7,p=0.001),但1年时SIEA腹部生理健康评分高于DIEP(平均差4.72,p=0.053),2年时差异不显著。2年时带蒂TRAM腹部生理健康评分较DIEP低7.2分(p=0.006)、较SIEA低7.8分(p=0.03),游离TRAM较DIEP低4.9分(p=0.04);双侧再造腹部生理健康评分显著低于单侧再造。

要点

  • 2年时SIEA较DIEP供区并发症发生率更高(OR 2.7,p=0.001)。
  • 2年时带蒂TRAM腹部生理健康评分较DIEP低7.2分(p=0.006)、较SIEA低7.8分(p=0.03)。
  • 2年时游离TRAM腹部生理健康评分较DIEP低4.9分(p=0.04)。

核心结论

  • 所有腹壁皮瓣均为可行的乳房再造选择,但DIEP和SIEA皮瓣的腹部生理健康评分高于带蒂TRAM和游离TRAM皮瓣。
  • SIEA皮瓣虽有不切开腹直肌前鞘的优势,但供区并发症发生率更高可能降低患者满意度。

研究设计与样本

  • 前瞻性多中心研究,纳入11个中心接受腹壁皮瓣乳房再造的患者,评估腹部供区和乳房并发症。
  • 患者报告结局采用BREAST-Q和患者报告结局测量信息系统问卷测量。
  • 采用混合效应回归模型评估手术方式对结局的影响。
  • 720例完成1年随访,587例完成2年随访。
  • 证据等级:治疗性,II级。

主要发现

  • 2年时SIEA较DIEP供区并发症发生率更高(OR 2.7,p=0.001)。
  • 1年时SIEA腹部生理健康BREAST-Q评分高于DIEP(平均差4.72,量表0至100,p=0.053),2年时该差异不显著。
  • 2年时带蒂TRAM腹部生理健康评分较DIEP低7.2分(p=0.006)、较SIEA低7.8分(p=0.03)。
  • 2年时游离TRAM腹部生理健康评分较DIEP低4.9分(p=0.04)。
  • 双侧再造腹部生理健康评分显著低于单侧再造。

关键数值与推荐

  • 2年时SIEA较DIEP供区并发症:OR 2.7(p=0.001)。
  • 1年时SIEA较DIEP腹部生理健康BREAST-Q评分:平均差4.72(量表0至100,p=0.053)。
  • 2年时带蒂TRAM较DIEP腹部生理健康评分:低7.2分(p=0.006)。
  • 2年时带蒂TRAM较SIEA腹部生理健康评分:低7.8分(p=0.03)。
  • 2年时游离TRAM较DIEP腹部生理健康评分:低4.9分(p=0.04)。

临床怎么用

  • 原文结论认为所有腹壁皮瓣均为可行的乳房再造选择,DIEP和SIEA皮瓣的腹部生理健康评分高于带蒂TRAM和游离TRAM皮瓣。
  • 原文结论指出SIEA皮瓣虽有不切开腹直肌前鞘的优势,但供区并发症发生率更高可能降低患者满意度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Abdominal flap reconstruction is the most popular form of autologous breast reconstruction. The current study compared complications and patient-reported outcomes after pedicled transverse rectus abdominis myocutaneous (TRAM), free TRAM, deep inferior epigastric perforator (DIEP), and superficial inferior epigastric artery (SIEA) flaps. METHODS: Patients undergoing abdominally based breast reconstruction at 11 centers were prospectively evaluated for abdominal donor-site and breast complications. Patient-reported outcomes were measured by the BREAST-Q and Patient-Reported Outcomes Measurement Information System surveys. Mixed-effects regression models were used to assess the effects of procedure type on outcomes. RESULTS: Seven hundred twenty patients had 1-year follow-up and 587 had 2-year follow-up. Two years after reconstruction, SIEA compared with DIEP flaps were associated with a higher rate of donor-site complications (OR, 2.7; p = 0.001); however, SIEA flaps were associated with higher BREAST-Q abdominal physical well-being scores compared with DIEP flaps at 1 year (mean difference, 4.72, on a scale from 0 to 100; p = 0.053). This difference was not significant at 2 years. Abdominal physical well-being scores at 2 years postoperatively were lower in the pedicled TRAM flap group by 7.2 points (p = 0.006) compared with DIEP flaps and by 7.8 points (p = 0.03) compared with SIEA flaps, and in the free TRAM flap group, scores were lower by 4.9 points (p = 0.04) compared with DIEP flaps. Bilateral reconstruction had significantly lower abdominal physical well-being scores compared with unilateral reconstruction. CONCLUSIONS: Although all abdominally based flaps are viable breast reconstruction options, DIEP and SIEA flaps are associated with higher abdominal physical well-being than pedicled and free TRAM flaps. Although SIEA flaps offer the advantage of not violating the fascia, higher rates of donor-site complications may diminish patient satisfaction. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, II.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Erdmann-Sager J, Wilkins EG, Pusic AL, et al. Complications and Patient-Reported Outcomes after Abdominally Based Breast Reconstruction: Results of the Mastectomy Reconstruction Outcomes Consortium Study. Plast Reconstr Surg. 2018. PMID: 29019862. doi:10.1097/PRS.0000000000004016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。