该前瞻性对比研究纳入16例烧伤患者共52个感兴趣区,在烧伤后第1天和第3天用激光多普勒成像、热成像、照片临床评估和实时临床评估四种方法判断烧伤深度,以21天内创面闭合为结局。结果显示第3天各方法准确性均高于第0天,激光多普勒成像准确性为92.3%,高于热成像的71.2%和照片临床评估的71.6%,实时临床检查准确性为88.5%;热成像扫描速度显著快于激光多普勒成像。

要点

  • 烧伤后第3天评估准确性高于第0天,激光多普勒成像第3天准确性达92.3%。
  • 激光多普勒成像准确性高于热成像(第3天92.3% vs 71.2%)和照片临床评估(71.6%)。
  • 热成像扫描时间显著快于激光多普勒成像,但诊断准确性较低。

核心结论

  • 激光多普勒成像在烧伤深度诊断准确性上优于热成像,可能因热成像易受环境因素影响。

研究设计与样本

  • 前瞻性对比评价研究,纳入16例烧伤患者共52个感兴趣区。
  • 烧伤深度用激光多普勒成像、热成像、照片临床评估和实时临床评估四种方法在烧伤后第1天和第3天判定。
  • 以激光多普勒成像通量和ΔT值预测结局(21天内创面闭合)。
  • 照片临床评估由4名设盲烧伤外科医生完成。

主要发现

  • 烧伤后第0天和第3天激光多普勒成像准确性分别为80.8%和92.3%。
  • 烧伤后第0天和第3天热成像准确性分别为55.8%和71.2%。
  • 烧伤后第0天和第3天照片临床评估准确性分别为62.5%和71.6%。
  • 实时临床检查准确性为88.5%。
  • 热成像扫描时间显著快于激光多普勒成像。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The accurate assessment of burn depth is challenging but crucial for surgical excision and tissue preservation. Laser Doppler Imaging (LDI) has gained increasing acceptance as a tool to aid depth assessment but its adoption is hampered by high costs, long scan times and limited portability. Thermal imaging is touted as a suitable alternative however few comparison studies have been done. METHODS: Sixteen burn patients with 52 regions of interests were analysed. Burn depth was determined using four methods LDI, thermal imaging, photographic and real-time clinical evaluation at day 1 and day 3. LDI flux and Delta T values were used for the prediction of outcomes (wound closure in <21 days). Photographic clinical evaluation of burn depth was performed by 4 blinded burn surgeons. RESULTS: Accuracy of assessment methods were greater on post burn day 3 compared to day 0. Accuracies of LDI on post burn day 0 and 3 were 80.8% and 92.3% compared to 55.8% and 71.2% for thermal imaging and 62.5% and 71.6% for photographic clinical assessment. Real-time clinical examination had an accuracy of 88.5%. Thermal imaging scan times were significantly faster compared to LDI. DISCUSSION: LDI outperforms thermal imaging in terms of diagnostic accuracy of burn depth likely due to the susceptibility of thermal imaging to environmental factors.