文献速递烧伤

烧伤患者血浆中因子XIa、因子IXa与组织因子活性分析

Analysis of factor XIa, factor IXa and tissue factor activity in burn patients.
PubMed 文献 · Burns · 2017-10-09

研究对56例烧伤患者入院后3周内最多20个时间点的471份血浆样本行凝血酶生成试验,用抑制性抗体检测组织因子(TF)、因子IXa(FIXa)与因子XIa(FXIa)活性。入院时53例中10例(19%)有活性TF、55例中53例(96%)有FXIa、55例中48例(87%)有FIXa;全部样本中TF占99/455(22%)、FXIa占424/471(90%)、FIXa占244/471(52%),健康人血浆均未检出三者活性。

要点

  • 烧伤患者血浆中普遍存在活性FXIa(424/471,90%)与FIXa(244/471,52%)。
  • 部分烧伤患者血浆可检出活性TF,入院时10/53(19%),全部样本99/455(22%)。
  • 健康个体血浆中未检测到TF、FXIa和FIXa活性。

核心结论

  • 首次报告烧伤患者大多数血浆样本存在活性FXIa和FIXa,其中相当一部分还具有活性TF。
  • 三种蛋白的浓度在很大范围内变化。

研究设计与样本

  • 研究纳入56例烧伤患者,采集入院后3周内最多20个时间点的血浆样本,总样本数471份。
  • 采用凝血酶生成试验,以针对TF、FIXa和FXIa的抑制性抗体评估其活性。
  • 因部分样本体积有限,并非所有样本均完成三种蛋白的检测。

主要发现

  • 入院时53例患者中10例(19%)血浆有活性TF,55例中53例(96%)有FXIa,55例中48例(87%)有FIXa。
  • 56例入组患者中34例(61%)在一个或多个时间点显示TF活性;全部患者在一个或多个时间点有FXIa,96%有FIXa。
  • 全部样本中,TF见于99/455份(22%),FXIa见于424/471份(90%),FIXa见于244/471份(52%)。
  • TF浓度相对较低,在0至2.1pM之间变化;FXIa浓度较高,部分样本超过100pM;多数含FIXa的样本其浓度为亚纳摩尔级。
  • 健康个体血浆中未检测到TF、FXIa和FIXa活性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: An elevated procoagulant activity observed in trauma patients is, in part, related to tissue factor (TF) located on blood cells and microparticles. However, analysis of trauma patient plasma indicates that there are other contributor(s) to the procoagulant activity. We hypothesize that factor (F)XIa and FIXa are responsible for an additional procoagulant activity in burn patients. METHODS: Multiple time-point plasma samples from 56 burn patients (total number of samples was 471; up to 20 time-points/patient collected in 3 weeks following admission) were evaluated in a thrombin generation assay using inhibitory antibodies to TF, FIXa and FXIa. RESULTS: Due to the limited volume of some samples, not all were analyzed for all three proteins. At admission, 10 of 53 patients (19%) had active TF, 53 of 55 (96%) had FXIa and 48 of 55 (87%) had FIXa in their plasma. 34 patients of 56 enrolled (61%) showed TF activity at one or more time-points. All patients had FXIa and 96% had FIXa at one or more time-points. Overall, TF was observed in 99 of 455 samples analyzed (22%), FXIa in 424 of 471 (90%) and FIXa in 244 of 471 (52%). The concentration of TF was relatively low and varied between 0 and 2.1pM, whereas that of FXIa was higher, exceeding 100pM in some samples. The majority of samples with FIXa had it at sub-nanomolar concentrations. No TF, FXIa and FIXa activity was detected in plasma from healthy individuals. CONCLUSIONS: For the first time reported, the majority of plasma samples from burn patients have active FXIa and FIXa, with a significant fraction of them having active TF. The concentration of all three proteins varies in a wide range.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Shupp JW, Prior SM, Jo DY, et al. Analysis of factor XIa, factor IXa and tissue factor activity in burn patients. Burns. 2017. PMID: 29032977. doi:10.1016/j.burns.2017.08.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。