文献速递烧伤创面修复

大面积烧伤后宏观血流动力学与全身微循环改变的相关性研究

Influences of Macrohemodynamic Conditions on Systemic Microhemodynamic Changes in Burns.
PubMed 文献 · Ann Plast Surg · 2016-01-01

本研究在大鼠模型中将热烧伤后4小时采集的烧伤血浆静脉输注给健康动物,进行2小时活体显微镜观察,评估宏观血流动力学与微循环参数的相关性。结果显示两组平均动脉压和心率无显著差异,宏观与微观血流动力学之间除T60时MAP与血浆外渗有显著相关外无其他显著相关;T120时烧伤组肠系膜微静脉出现明显微血管烧伤性水肿。结论提示宏观血流动力学稳定不一定改善微循环障碍。

要点

  • 烧伤后宏观血流动力学稳定不一定代表微循环改善
  • 仅T60时MAP与血浆外渗存在显著相关
  • T120时烧伤组微静脉出现明显微血管烧伤性水肿

核心结论

  • 宏观血流动力学稳定不一定对微循环障碍产生正面影响,这一现象在烧伤中尚未被证实,但在脓毒症中已有充分描述。

研究设计与样本

  • 大鼠模型:将热烧伤后4小时采集的烧伤血浆静脉输注给健康动物进行2小时活体显微镜观察(烧伤组),对照组输注shamburn血浆。
  • 烧伤组观察15只动物的31条肠系膜微静脉,shamburn组观察16只动物的30条肠系膜微静脉。

主要发现

  • 两组平均动脉压和心率均在可接受范围内,组内及组间均无显著差异。
  • 除T60时MAP与血浆外渗存在显著相关外,烧伤组和shamburn组均未观察到宏观与微观血流动力学参数间的显著相关。
  • T120时烧伤组肠系膜微静脉明显显示微血管烧伤性水肿,而shamburn组微静脉未见此表现。

临床怎么用

  • 临床监测宏观血流动力学稳定时仍需关注微循环状态,不宜仅凭宏观参数判断微循环改善。

局限性

  • 研究为大鼠模型,结果外推到临床需谨慎。
  • 需进一步研究明确微循环专项监测是否可为烧伤治疗提供新途径。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The clinical course after major burns is characterized by microcirculatory changes and consecutive capillary leakage. However, current clinical monitoring does not properly assess microcirculation, whereas macrohemodynamic changes are continuously evaluated. Here, we assess if macrohemodynamic and microhemodynamic parameters after burn trauma are correlated in a rat model. METHODS: Burn plasma harvested from donor rats 4 hours after thermal injury (30% total body surface area, 100 °C water, 12 seconds) was administered intravenously to healthy animals during 2 hours of intravital microscopy (burn group [BG]). Shamburn plasma (same procedure but water at 37°C) was transferred for negative controls (shamburn group [SBG]). Intravital microscopy was performed at 0, 60, and 120 minutes to assess capillary leakage measuring fluorescein isothiocyanate-albumin extravasation. Macrocirculation was assessed using mean arterial pressure and heart rate, whereas microcirculation was evaluated using red blood cell velocity, venular diameter, venular wall shear rate and plasma extravasation at 0, 60, and 120 minutes in postcapillary venules. RESULTS: Thirty mesenteric venules (16 animals) in SBG and 31 mesenteric venules (15 animals) in BG were observed during intravital microscopy. Mean arterial pressure and heart rate remained within acceptable margins and showed no significant differences, neither within nor between groups. Significant correlations between macrohemodynamic and microhemodynamic conditions were neither observed for BG nor SBG, except from a significant correlation of MAP and plasma extravasation at T60. However, at T120 mesenteric venules in the BG clearly showed microvascular burn edema, whereas venules in SBG did not. CONCLUSIONS: Stabilization of macrohemodynamic conditions may not necessarily have positive effects on microcirculatory derangements-a fact that has not been shown for burns yet, that is-however, well described for sepsis. Further studies are required to show whether distinct monitoring of microcirculation may offer new approaches for burn trauma treatment.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Hernekamp JF, Neubrech F, Cordts T, et al. Influences of Macrohemodynamic Conditions on Systemic Microhemodynamic Changes in Burns. Ann Plast Surg. 2016. PMID: 28792428. doi:10.1097/SAP.0000000000000868

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。