生物阻抗谱监测小面积烧伤肿胀干预的可靠性与有效性
本研究检验生物阻抗谱(BIS)测量局部烧伤创面水肿在不同敷料条件(无敷料、非银敷料、银敷料)和三种电极位置下的信度与效度。BIS 重测信度极佳(ICC=0.999-1.00,95%CI 0.999-1.00),电阻变量随肢体节段体积减小而显著升高(p≤0.01),银敷料使电阻显著降低而非银敷料使其升高(p<0.01),并开发了银敷料使用时的电阻校正算法。BIS 或可用于临床监测烧伤创面水肿的局部变化。
要点
- BIS 测量烧伤局部水肿的重测信度极佳(ICC=0.999-1.00)。
- 电阻随肢体节段体积减小而升高,支持其反映水肿变化。
- 银敷料显著降低电阻,非银敷料升高电阻,需校正算法。
核心结论
- BIS 测量局部烧伤创面水肿具有极佳重测信度,且电阻变化与肢体节段体积变化显著相关,可能用于临床监测水肿干预效果。
研究设计与样本
- 方法学信度与效度研究,在无敷料、非银敷料和银敷料三种条件下及三种电极位置重复测量 BIS 电阻变量。
主要发现
- BIS 电阻变量(R0、Ri、Rinf)重测组内相关系数为 0.999-1.00(95%CI 0.999-1.00),无系统性差异。
- R0、Ri 和 Rinf 随局部肢体节段体积减小而显著升高(p≤0.01)。
- 银敷料原位时电阻显著降低(p<0.01),非银敷料原位时电阻显著升高(p<0.01)。
- 每种敷料条件与局部肢体节段体积之间存在显著交互作用(p<0.01)。
临床怎么用
- BIS 可用于临床监测小面积烧伤局部创面水肿的动态变化。
- 使用银敷料时需应用所开发的电阻校正算法解读 BIS 电阻值。
局限性
- 研究聚焦小面积烧伤,结论外推至大面积烧伤需谨慎。
- 摘要未报告样本量及具体电极位置等细节。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The control of edema in burn injured patients is a priority as it can impede the wound healing process. Bioimpedance spectroscopy (BIS) has been identified as a method of swelling assessment that has merit after burns. The aim of this study was to examine the reliability and validity of BIS in the measurement of localised burn wound edema across (1) different dressing conditions (no dressing, non silver and silver dressings) and (2) three electrode positions. BIS resistance (R) was hypothesised to be inversely proportional to fluid (edema) volume. BIS was collected in triplicate for all conditions of interest. BIS repeated measures demonstrated excellent concordance for all BIS resistance variables (R0, Ri, Rinf) (intraclass correlation coefficient=0.999-1.00, 95% confidence intervals 0.999-1.00) without a systematic difference. Multilevel mixed effects linear regression analysis examined the effect of electrode position and dressing condition on BIS resistance variables. R0, Ri and Rinf significantly increased with decreasing localised limb segment volume (p≤0.01). Resistance was significantly (1) reduced when a silver dressing was in situ (p<0.01) and (2) increased when a non-silver dressing was insitu (p<0.01). There was a significant interaction between each dressing condition and localised limb segment volume (p<0.01). An algorithm was developed to adjust resistance values when a silver dressing is in use. BIS may be used clinically to monitor localised changes in burn wound edema.
引用
- Kenworthy P, Grisbrook TL, Phillips M, et al. Bioimpedance spectroscopy: A technique to monitor interventions for swelling in minor burns. Burns. 2017. PMID: 28781137. doi:10.1016/j.burns.2017.04.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。