文献速递乳房整形与再造

术前用Kinect三维成像选择单侧乳房再造假体

Preoperative implant selection for unilateral breast reconstruction using 3D imaging with the Microsoft Kinect sensor.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2017-04-23

本研究纳入10例单侧假体乳房再造患者,术前术后用Kinect传感器三维成像,比较七种成像配置与四种乳房边界定义方法的体积测量可重复性,并建立线性模型预测假体体积。结果显示最可重复的边界标注为椭圆追踪乳房下皱襞加胸壁平面(重复性系数70 ml),最佳成像体位为坐位举臂、Kinect居中(重复性系数141 ml),术前健康乳房体积预测假体体积R²=0.78、预测标准误120 ml,留一法验证61%病例预测误差在10%以内、17%病例误差>30%。

要点

  • 椭圆追踪下皱襞加胸壁平面标注乳房边界最可重复(重复性系数70 ml)。
  • 坐位举臂、Kinect居中成像时健康乳房体积测量最可重复(141 ml)。
  • 术前健康乳房体积线性模型预测假体体积R²=0.78,预测标准误120 ml。

核心结论

  • Kinect三维成像术前测量健康乳房体积有望辅助单侧乳房再造的假体选择与采购,以最大化对称性。

研究设计与样本

  • 10例患者接受单侧假体乳房再造,术前术后行Kinect三维成像。
  • 比较七种患者体位与Kinect位置配置对体积测量的适用性。
  • 比较四种乳房边界定义方法的自动体积计算,并评估五次重复的可重复性。

主要发现

  • 最可重复的乳房边界标注为椭圆追踪乳房下皱襞加胸壁平面,重复性系数70 ml。
  • 术前术后健康乳房体积测量最可重复的成像位置为坐位举臂、Kinect居中,重复性系数141 ml。
  • 由术前健康乳房体积导出的线性模型预测假体体积R²=0.78,预测标准误120 ml。
  • 乳房切除标本重量与有经验外科医生选择的预测能力相似(均R²=0.74,标准误141/142 ml)。
  • 留一法验证中61%病例三维成像预测假体体积误差在10%以内,17%病例误差>30%。

关键数值与推荐

  • 乳房边界标注重复性系数70 ml(椭圆追踪下皱襞加胸壁平面)。
  • 成像位置重复性系数141 ml(坐位举臂、Kinect居中)。
  • 假体体积预测线性模型R²=0.78,预测标准误120 ml。
  • 乳房切除标本重量与外科医生选择预测假体体积均R²=0.74,标准误141/142 ml。
  • 留一法验证:61%病例预测误差≤10%,17%病例误差>30%。

临床怎么用

  • 术前可用Kinect三维成像测量健康乳房体积,结合线性模型辅助假体尺寸选择。
  • 成像时建议患者坐位举臂、Kinect居中,以提高体积测量可重复性。
  • 乳房边界自动标注可采用椭圆追踪下皱襞加胸壁平面法。

局限性

  • 样本量仅10例,结论外推需谨慎。
  • 留一法验证中17%病例假体体积预测误差>30%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: This study aimed to investigate whether breast volume measured preoperatively using a Kinect 3D sensor could be used to determine the most appropriate implant size for reconstruction. METHODS: Ten patients underwent 3D imaging before and after unilateral implant-based reconstruction. Imaging used seven configurations, varying patient pose and Kinect location, which were compared regarding suitability for volume measurement. Four methods of defining the breast boundary for automated volume calculation were compared, and repeatability assessed over five repetitions. RESULTS: The most repeatable breast boundary annotation used an ellipse to track the inframammary fold and a plane describing the chest wall (coefficient of repeatability: 70 ml). The most reproducible imaging position comparing pre- and postoperative volume measurement of the healthy breast was achieved for the sitting patient with elevated arms and Kinect centrally positioned (coefficient of repeatability: 141 ml). Optimal implant volume was calculated by correcting used implant volume by the observed postoperative asymmetry. It was possible to predict implant size using a linear model derived from preoperative volume measurement of the healthy breast (coefficient of determination R2 = 0.78, standard error of prediction 120 ml). Mastectomy specimen weight and experienced surgeons' choice showed similar predictive ability (both: R2 = 0.74, standard error: 141/142 ml). A leave one-out validation showed that in 61% of cases, 3D imaging could predict implant volume to within 10%; however for 17% of cases it was >30%. CONCLUSION: This technology has the potential to facilitate reconstruction surgery planning and implant procurement to maximise symmetry after unilateral reconstruction.