解剖型乳房假体旋转是否值得担忧?旋转易感因素的统计分析
该研究回顾瑞典单术者6.5年间531例初次隆乳使用粗面解剖型假体的病例,分析假体旋转率及其与术前罩杯、分娩史和体重指数的关系。结果显示20枚假体(1.88%;95%CI 1.15–2.89%)在19例患者(3.58%;95%CI 2.17–5.53%)中发生旋转,1例(0.22%)双侧旋转,其余为单侧。旋转与分娩史或体重指数升高无统计学显著相关,但与术前罩杯从A增至C呈上升趋势。作者认为规范选择假体并精细操作可使旋转率很低,不应视为使用解剖型假体的劣势。
要点
- 粗面解剖型假体隆乳的假体旋转率为1.88%,患者层面为3.58%。
- 旋转与分娩史或体重指数升高无统计学显著相关。
- 旋转率随术前罩杯从A增至C呈上升趋势。
核心结论
- 规范选择假体并在精细操作下充分剥离腔隙时,解剖型假体旋转率很低,不应视为其使用劣势。
研究设计与样本
- 单中心、单术者回顾性病例系列,纳入531例初次隆乳使用粗面解剖型假体的患者,随访6.5年。
- 证据等级为风险类III级。
主要发现
- 20枚假体(1.88%;95%CI 1.15–2.89%)在19例患者(3.58%;95%CI 2.17–5.53%)中发生旋转。
- 1例患者(0.22%)双侧假体均旋转,其余患者为单侧旋转。
- 未发现旋转与既往分娩或体重指数升高有统计学显著相关。
- 旋转率与术前罩杯从A增至C呈上升趋势。
临床怎么用
- 术前评估罩杯大小,对罩杯较大者关注旋转风险并精细剥离腔隙以降低旋转率。
局限性
- 单中心、单术者回顾性系列,可能存在选择偏倚,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Since their introduction in 1993, anatomical implants have provided a more natural appearance in breast augmentation, and many surgeons advocate their use and promote the good aesthetic results. However, the risk of implant rotation makes some of them reluctant to use these devices. The rotation rate varies among authors. METHODS: The authors present a 6.5-year series of 531 patients who underwent primary breast augmentation with macrotextured anatomical implants in a Swedish facility performed by one consultant surgeon (P.M.). The authors examined the rotation rate and the correlation with possible predisposing factors such as preoperative breast cup size, childbirth, and body mass index. RESULTS: A total of 20 implants (1.88 percent; 95 percent CI, 1.15 to 2.89 percent) in 19 patients (3.58 percent; 95 percent CI, 2.17 to 5.53 percent) were rotated. In one patient (0.22 percent), both implants rotated, whereas in the remaining patients, the rotation was unilateral. The authors were unable to establish a statistically significant correlation between implant rotation and previous childbirth or increased body mass index. However, there was a relation between rotation rate and preoperative breast cup size that showed an upward trend as the cup size increased from A to C. CONCLUSION: The authors believe that if the implant is correctly selected and the operation is performed meticulously with proper pocket dissection, the rotation rate is minimal and it should not be considered a disadvantage for the use of anatomical implants. CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, III.
引用
- Montemurro P, Papas A, Hedén P, et al. Is Rotation a Concern with Anatomical Breast Implants? A Statistical Analysis of Factors Predisposing to Rotation. Plast Reconstr Surg. 2017. PMID: 28538561. doi:10.1097/PRS.0000000000003387
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。