放疗技术演进对植入物乳房重建的影响
结果显示放疗组总体并发症率更高,皮肤最大剂量与并发症相关,俯卧位可降低皮肤最大剂量但未显著减少并发症。
要点
- 放疗组总体并发症率35.2%,未放疗组14.4%,差异显著。
- 皮肤最大剂量及1cc皮肤最大剂量与并发症相关。
- 俯卧位较仰卧位显著降低皮肤最大剂量(58.5 Gy vs 61.7 Gy)。
核心结论
- 放疗技术演进中应像关注心脏和肺剂量一样关注皮肤最大剂量以优化重建结局。
- 俯卧位显著降低皮肤最大剂量,并有降低重建并发症的趋势但未达统计学显著。
研究设计与样本
- 平均随访时间分别为24.7个月和26.0个月(p=0.49)。
主要发现
- 放疗组总体并发症率35.2%,未放疗组14.4%(p<0.01)。
- 皮肤最大剂量与并发症相关(p=0.05),1cc皮肤最大剂量与并发症相关(p=0.01)。
- 不同放疗技术(三维适形、调强、野中野、混合技术)未影响并发症率。
- 俯卧位较仰卧位显著降低皮肤最大剂量(58.5 Gy vs 61.7 Gy,p=0.05),但并发症率无显著差异。
关键数值与推荐
- 放疗组总体并发症率35.2% vs 未放疗组14.4%(p<0.01)。
- 皮肤最大剂量p=0.05,1cc皮肤最大剂量p=0.01与并发症相关。
- 俯卧位皮肤最大剂量58.5 Gy vs 仰卧位61.7 Gy(p=0.05)。
临床怎么用
- 在放疗计划中应关注皮肤最大剂量,将其作为优化重建结局的考量因素。
- 可考虑俯卧位放疗以降低皮肤最大剂量,但需进一步研究确认对并发症的影响。
局限性
- 回顾性单中心研究,证据等级为治疗性III级。
- 俯卧位与仰卧位比较中并发症率差异未达统计学显著。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patients undergoing implant-based reconstruction in the setting of postmastectomy radiation therapy suffer from increased complications and inferior outcomes compared with those not irradiated, but advances in radiation delivery have allowed for more nuanced therapy. The authors investigated whether these advances impact patient outcomes in implant-based breast reconstruction. METHODS: Retrospective chart review identified all implant-based reconstructions performed at a single institution from November of 2010 to November of 2013. These data were cross-referenced with a registry of patients undergoing breast irradiation. Patient demographics, treatment characteristics, and outcomes were analyzed. RESULTS: Three hundred twenty-six patients (533 reconstructions) were not irradiated, whereas 83 patients (125 reconstructions) received radiation therapy; mean follow-up was 24.7 months versus 26.0 months (p = 0.49). Overall complication rates were higher in the irradiated group (35.2 percent versus 14.4 percent; p < 0.01). Increased maximum radiation doses to the skin were associated with complications (maximum dose to skin, p = 0.05; maximum dose to 1 cc of skin, p = 0.01). Different treatment modalities (e.g., three-dimensional conformal, intensity-modulated, field-in-field, and hybrid techniques) did not impact complication rates. Prone versus supine positioning significantly decreased the maximum skin dose (58.5 Gy versus 61.7 Gy; p = 0.05), although this did not translate to significantly decreased complication rates in analysis of prone versus supine positioning. CONCLUSIONS: As radiation techniques evolve, the maximum dose to skin should be given consideration similar to that for heart and lung dosing, to optimize reconstructive outcomes. Prone positioning significantly decreases the maximum skin dose and trends toward significance in reducing reconstructive complications. With continued study, this may become clinically important. Interdepartmental studies such as this one ensure quality of care. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.
引用
- Muresan H, Lam G, Cooper BT, et al. Impact of Evolving Radiation Therapy Techniques on Implant-Based Breast Reconstruction. Plast Reconstr Surg. 2017. PMID: 28538549. doi:10.1097/PRS.0000000000003341
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。