文献速递烧伤创面修复

标准化实验烧伤模型的新型装置

A new apparatus for standardization of experimental burn models.
PubMed 文献 · Burns · 2017-02-06

本研究设计了一种可实时记录温度、压力和接触时间的定制装置,用于标准化实验烧伤模型。在Sprague-Dawley大鼠中设置60±1°C或80±1°C、低或高压力共四组,测量烧伤深度占健康皮肤厚度的百分比。结果显示温度和压力均显著影响烧伤深度百分比,且两者无优先级,不记录实时变量则无法实现标准烧伤模型。

要点

  • 实时记录温度、压力和时间是标准化烧伤模型的关键。
  • 压力和温度均显著影响烧伤深度百分比,无优先级。
  • 定制装置可控制变量,有助于实现标准烧伤深度。

核心结论

  • 不记录实时温度和压力则无法实现标准烧伤模型,标准烧伤深度需控制变量。

研究设计与样本

  • 定制装置可设定并记录实时温度、压力和时间,垂直角度确保压力施加,Sprague-Dawley大鼠随机分为四组:60±1°C低压力、60±1°C高压力、80±1°C低压力、80±1°C高压力。

主要发现

  • 低压力组间(G60WFL vs G80WFL)压力无显著差异(p=0.1704),高压力组间(G60WFH vs G80WFH)压力无显著差异(p=0.2369)。
  • 60°C组中高压力较低压力显著增加烧伤深度百分比(p=0.0125),80°C组中高压力较低压力显著增加(p<0.0001)。
  • 低压力组中80°C较60°C显著增加烧伤深度百分比(p<0.0001),高压力组中80°C较60°C显著增加(p<0.0001)。

关键数值与推荐

  • 烧伤温度设为60±1°C或80±1°C,压力分为低压力和高压力,以烧伤深度占健康皮肤厚度的百分比进行统计分析。

临床怎么用

  • 在实验烧伤研究中应使用可实时记录温度、压力和时间变量的装置,以确保模型标准化和结果可比性。

局限性

  • 原文未报告

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Burns have severe economic burden for families and countries therefore its treatment modalities have utmost importance. Several study both experimental or clinic has been reported accordingly. Although contact burns were frequently used models, most of them were manually designed. The elapsed time was recorded only. However, the real time contact surface temperature (T) and weight force (WF) were fundamental characteristics of a burn model. The aim of this study is to create a standard burn model with recording real time variables on behalf of custom designed apparatus. METHODS: A custom designed apparatus was manufactured in which the variables of real time T, WF and elapsed time could be set and record. A vertical angle was provided to ensure the applied WF. And hence, Sprague-Dawley rats were randomly divided into four groups: (1) Burned at 60±1°C with low WF(G60WFL), (2) Burned at 60±1°C with high WF(G60WFH), (3) Burned at 80±1°C with low WF(G80WFL), (4) Burned at 80±1°C with high WF(G80WFH). The healthy skin thickness and burn depth were measured. The percentage of burn depth to healthy skin was used for statistical analysis. RESULTS: Constant variables T and WF were achieved. The pressure applied on skin was not significant between low [G60WFL vs G80WFL, (p=0.1704)] and high [G60WFH vs G80WFH (p=0.2369)] WF groups. However the percentage of burn depth was increasing owing to applied WF in 60°C group [G60WFL vs G60WFH, (p=0.0125)] and in 80°C group [G80WFL vs G80WFH (p<0.0001)]. And also the percentage was significantly increasing owing to set T, in low WF group [G60WFL vs G80WFL (p<0.0001)] and high WF group [G60WFH vs G80WFH (p<0.0001)]. Besides neither T nor WF has priority. CONCLUSION: Without recording the real time T and WF, it is infeasible to achieve a standard burn model. For a standard depth of burn, variables should be under control, as if our custom designed apparatus.