烧伤ICU实践委员会推行酒精浸渍端口保护器降低导管相关血流感染
该文报告烧伤ICU实践委员会采用Iowa循证实践模型,引入商用酒精浸渍中心静脉导管端口保护器,以降低导管相关血流感染(CLABSI)发生率。前后对照设计显示,干预后CLABSI率从基线7.3/1000导管日降至2013年平均3.04/1000导管日。结论认为该保护器可减少烧伤单元CLABSI发生。
要点
- 烧伤患者因开放伤口、长ICU停留、频繁导管使用和免疫抑制而CLABSI风险高。
- 引入酒精浸渍中心静脉端口保护器后CLABSI率由7.3降至3.04/1000导管日。
- 该实践由单元实践委员会采用Iowa循证实践模型推动实施。
核心结论
- 引入酒精浸渍中心静脉导管端口保护器可降低烧伤单元CLABSI发生率。
研究设计与样本
- 采用前后干预对照设计,由单元实践委员会以Iowa循证实践模型指导实施。
主要发现
- CLABSI率从基线7.3/1000导管日降至2013日历年平均3.04/1000导管日。
关键数值与推荐
- 引入商用酒精浸渍中心静脉导管端口保护器作为降低CLABSI的干预措施。
临床怎么用
- 烧伤ICU可考虑引入酒精浸渍端口保护器以降低CLABSI发生率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Burn patients are an especially high-risk population for development of central line associated bloodstream infections (CLABSI) due to open wounds, extended length of intensive care unit stay, frequent use of central venous catheters, and generally immunocompromised state. Implementing evidence-based practices to prevent these infections is a 2014 National Patient Safety Goal per The Joint Commission. OBJECTIVES: The purpose of this project was introduction of a commercially available alcohol impregnated central venous line port protector to reduce the incidence of CLABSI in the burn unit. METHODS: The Iowa Model for Implementing Evidenced-Based Practice was used to guide this intervention conducted by the Unit Practice Council. A pre- and post-intervention design compared rates of CLABSI before and after introduction of the port protectors. RESULTS: CLABSI infection rates decreased following the intervention from baseline of 7.3 per 1000 line days to an average of 3.04 per 1000 line days during calendar year 2013. CONCLUSIONS: Introduction of an alcohol impregnated central venous line port protector can reduce the incidence of CLABSI in a burn unit.
引用
- Martino A, Thompson L, Mitchell C, et al. Efforts of a Unit Practice Council to implement practice change utilizing alcohol impregnated port protectors in a burn ICU. Burns. 2017. PMID: 28139260. doi:10.1016/j.burns.2017.01.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。