带蒂颞肌瓣用于颅颌面重建:366例35年临床经验
单中心1978至2012年共施行366例带蒂颞肌瓣,以1994年开展游离瓣为界分两阶段。1994年后主要用于上颌、下颌、口咽缺损及面瘫动力重建和眶内填充;全瓣坏死率1.6%、部分坏死率10.7%,供区多孔聚乙烯均匀使用后材料外露率由17.1%降至7.9%。
要点
- 1994年后带蒂颞肌瓣适应证限于眶内填充、单侧上颌切除缺损填充及选择性面瘫动力重建。
- 全瓣坏死率1.6%,部分瓣坏死率10.7%。
- 供区均匀使用多孔聚乙烯后材料外露率由17.1%降至7.9%。
核心结论
- 带蒂颞肌瓣在颅颌面重建中仍有多种应用,游离瓣普及后其适应证收窄为眶内填充、单侧上颌切除缺损填充及选择性面瘫动力重建。
研究设计与样本
- 单中心1978至2012年共366例带蒂颞肌瓣的回顾性系列,按1994年前后分两阶段,证据等级为治疗性IV级。
主要发现
- 1994年后颞肌瓣最常用于上颌、下颌和口咽缺损重建,以及面瘫动力重建和眶内缺损填充。
- 并发症包括全瓣坏死1.6%和部分瓣坏死10.7%。
- 供区材料外露率在多孔聚乙烯均匀使用后由17.1%降至7.9%。
关键数值与推荐
- 当前带蒂颞肌瓣适应证为:先天性或获得性无眼球的眶内填充;单侧上颌切除缺损填充;选择性面神经麻痹病例的面瘫动力重建。
临床怎么用
- 在游离瓣可用条件下,仍可对眶内填充、单侧上颌切除缺损填充及选择性面瘫病例选用带蒂颞肌瓣。
- 供区重建宜均匀使用多孔聚乙烯以降低材料外露风险。
局限性
- 为单中心回顾性系列,证据等级IV级;原文未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In the past 130 years, the temporalis muscle flap has been used for a variety of different indications. In this age of microsurgery and perforator flaps, the temporalis muscle flap still has many useful applications for craniofacial reconstruction. METHODS: Three hundred sixty-six temporalis muscle flaps were performed in a single center between 1978 and 2012. The authors divided the cases into two series-before and after 1994-because, after 1994, they started to perform free flap reconstructions, and indications for reconstruction with a temporalis muscle flap were changed RESULTS:: In the series after 1994, flaps were most commonly used for reconstruction of defects in the maxilla, mandible, and oropharynx, in addition to facial reanimation and filling of orbital defects. Complications included total flap necrosis (1.6 percent) and partial flap necrosis (10.7 percent). The rate of material extrusion at the donor site decreased after porous polyethylene was uniformly used for reconstruction from 17.1 to 7.9 percent. CONCLUSIONS: The pedicled temporalis muscle flap continues to have many applications in craniofacial reconstruction. With increasing use of free flaps, the authors' indications for the pedicled temporalis muscle flap are now restricted to (1) orbital filling for congenital or acquired anophthalmia; (2) filling of unilateral maxillectomy defects; and (3) facial reanimation in selected cases of facial nerve palsy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Spanio di Spilimbergo S, Nordera P, Mardini S, et al. Pedicled Temporalis Muscle Flap for Craniofacial Reconstruction: A 35-Year Clinical Experience with 366 Flaps. Plast Reconstr Surg. 2017. PMID: 28121882. doi:10.1097/PRS.0000000000003011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。