短期瘢痕质量对轻中度烧伤最终瘢痕结局的预测效度:基于POSAS评估
该研究纳入141例最大烧伤面积20%的患者,在伤后3个月和>18个月进行POSAS、Dermaspectrometer®和Cutometer®评估,以检验POSAS对最终瘢痕质量的预测效度。结果显示患者量表区分长期瘢痕质量良好与减低的AUC为0.728(CI 0.640-0.804),观察者量表AUC为0.854(CI 0.781-0.911);疼痛和僵硬(患者)以及柔软度和平整度(观察者)是长期瘢痕质量减低的显著预测因子。结论认为伤后3个月的早期POSAS评估可充分预测最终瘢痕质量。
要点
- 伤后3个月POSAS观察者量表对长期瘢痕质量区分能力良好(AUC 0.854)。
- 患者量表区分能力 adequate(AUC 0.728),疼痛和僵硬为显著预测因子。
- POSAS信度可靠,3个月结构效度 adequate 但>18个月下降。
核心结论
- 伤后3个月的早期POSAS评估可充分预测轻中度烧伤患者的最终瘢痕质量。
研究设计与样本
- 纳入荷兰烧伤中心141例最大TBSA烧伤20%的患者,平均TBSA 5.2%(±4.5),在伤后3个月和>18个月进行两次瘢痕评估。
- 评估工具包括POSAS、Dermaspectrometer®(颜色)和Cutometer®(弹性),预测效度通过区分能力、两次评估间相关性及线性回归分析确定。
主要发现
- 患者量表区分长期瘢痕质量良好与减低的AUC为0.728(CI 0.640-0.804),观察者量表AUC为0.854(CI 0.781-0.911)。
- T3与T>18之间各条目评分的相关性至少为 adequate。
- 条目水平上,疼痛和僵硬(患者量表)以及柔软度和平整度(观察者量表)是长期瘢痕质量减低的显著预测因子。
- POSAS信度可靠,结构效度在3个月时为 adequate,但在>18个月时下降。
临床怎么用
- 可在伤后3个月使用POSAS早期评估瘢痕,以预测最终瘢痕质量并识别高风险患者。
- 关注患者报告的疼痛和僵硬以及观察者评估的柔软度和平整度,作为长期瘢痕质量减低的预测指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study was to assess the predictive validity of the Patient and Observer Assessment Scale (POSAS), in order to determine whether it can be used to predict final scar quality. METHODS: Patients with a maximum TBSA burned of 20% who were treated in a Dutch burn center and participated in two scar assessments at 3 months and >18 months post-burn were included. Scar quality assessment consisted of the POSAS, Dermaspectrometer® (color) and Cutometer® (elasticity). Predictive validity was determined in three ways: (1) the discriminative ability to distinguish good from reduced long term scar quality, (2) correlations between POSAS items score at the two subsequent assessments and (3) linear regression was conducted to identify POSAS items as independent predictors. Additionally, reliability, construct validity and interpretability were assessed. RESULTS: A total of 141 patients were included with a mean TBSA burned of 5.2% (±4.5). The ability of the Patient scale to discriminate between good and reduced long term scar quality was adequate with an area under the curve (AUC) of 0.728 (CI 0.640-0.804), the ability of the Observer scale was good with an AUC of 0.854 (CI 0.781-0.911). Correlations between items scored T3 and T>18 were at least adequate. On item level, pain and stiffness (Patient) and pliability and relief (Observer) were identified as significant predictors for reduced long term scar quality. The POSAS was reliable, construct validity was adequate at three months but declined at >18 months. CONCLUSION: This study found that final scar quality can be adequately predicted by an early POSAS assessment at three months.
引用
- Goei H, van der Vlies CH, Tuinebreijer WE, et al. Predictive validity of short term scar quality on final burn scar outcome using the Patient and Observer Scar Assessment Scale in patients with minor to moderate burn severity. Burns. 2016. PMID: 28040371. doi:10.1016/j.burns.2016.10.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。