自体或扩张器乳房再造后的乳头再造:多模式与三维分析
中位随访32-34个月后,再造乳头突度仅为对侧的55-60%,体积为12±8%(皮瓣组)和12±7%(扩张器组),但患者总体满意度可接受(VAS 4.1±3.5)。
要点
- 再造乳头三维收缩明显,突度仅为对侧的55-60%,体积降至12±7-8%。
- 扩张器再造后乳晕敏感性优于自体皮瓣再造。
- 尽管乳头乳晕不对称显著,患者总体满意度仍可接受。
核心结论
- 乳头再造后体积和突度与健侧存在巨大不对称,但扩张器与皮瓣再造之间无差异,患者满意度可接受。
主要发现
- 中位随访32个月(扩张器组)和34个月(皮瓣组),三维激光扫描显示再造乳头突度为对侧的55-60%。
- 乳头体积为12±8%(皮瓣再造)和12±7%(扩张器再造)。
- 乳晕敏感性在扩张器再造后表现更好。
- 患者总体满意度VAS为4.1±3.5。
临床怎么用
- 乳头再造前应告知患者术后乳头体积和突度可能显著小于健侧。
- 扩张器乳房再造后乳晕敏感性可能优于自体皮瓣再造。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Little is known about the influence of the underlying tissue as donor for nipple-areola complex (NAC) reconstruction. Also, there is a complete lack of knowledge about the fate of nipple volume. OBJECTIVES: The goal of this retrospective, single-institution study was to analyze a case series after nipple reconstruction using a multimodal evaluation including 3-dimensional (3D) laser scanner analyses. METHODS: Unilateral mastectomy patients after either expander-based or autologous breast reconstruction using the skate flap were included. NAC caliper measurement of nipple and areola size was performed. 3D laser scanner analysis (Minolta Vivid 900) was used to calculate nipple volume, measurement of nipple, and areolar projection and diameter. Sensitivity was evaluated using the Semmes Weinstein test and patient satisfaction by a visual analog scale (VAS 1-10). RESULTS: A total of 10 patients were included in the expander group and 12 patients were included in the flap group. After a median follow-up period of 32 months in the expander group and 34 months in the flap group, non-contact 3D laser surface scanning revealed a difference in projection of 55 to 60% compared to the contralateral side. The contraction in all 3 dimensions led to a dramatic difference in nipple volume with 12 ± 8% (flap reconstructions) and 12 ± 7% (expander reconstructions). Sensitivity of the areola showed better values after expander-based reconstruction. Despite the significant discrepancy in nipple volume and projection as well as areolar diameter, overall patient satisfaction was acceptable (VAS 4.1 ± 3.5). CONCLUSIONS: Volume assessment revealed a massive asymmetry to the intact nipple but not between expander and flap reconstructions. Although asymmetry of the areola and nipple remains, patient satisfaction is acceptable. LEVEL OF EVIDENCE 4.
引用
- Tremp M, di Summa PG, Schaakxs D, et al. Nipple Reconstruction After Autologous or Expander Breast Reconstruction: A Multimodal and 3-Dimensional Analysis. Aesthet Surg J. 2016. PMID: 27986753. doi:10.1093/asj/sjw181
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。