谐波手术刀与双极电凝在DIEP皮瓣手术中的剥离比较:连续队列研究
该连续队列研究纳入2015年1月至8月24例立即行DIEP皮瓣抬起的患者,12例用双极电凝、12例用谐波手术刀。谐波手术刀组总手术时间和皮瓣抬起时间均显著缩短,但引流体积和住院时间无统计学差异。结论认为谐波手术刀可能是电凝的可靠高效替代。
要点
- 谐波手术刀组总手术时间305.2 min,双极电凝组380.3 min,差异有统计学意义(p=0.002)。
- 谐波手术刀组皮瓣抬起时间59.8 min,双极电凝组145.9 min,差异有统计学意义(p<0.0001)。
- 两组引流体积和住院时间无统计学差异。
核心结论
- 谐波手术刀在DIEP皮瓣手术中可能比双极电凝更可靠、更高效。
研究设计与样本
- 连续队列研究,2015年1月至8月纳入24例立即行DIEP皮瓣抬起的患者,双极电凝组12例、谐波手术刀组12例。
主要发现
- 谐波手术刀组总手术时间305.2 min,双极电凝组380.3 min,差异有统计学意义(p=0.002)。
- 谐波手术刀组皮瓣抬起时间59.8 min,双极电凝组145.9 min,差异有统计学意义(p<0.0001)。
- 两组引流体积和住院时间无统计学差异。
- 两组临床特征(平均年龄、体重指数、皮瓣重量)可比。
临床怎么用
- 在DIEP皮瓣手术中可考虑使用谐波手术刀替代双极电凝,以缩短手术时间和皮瓣抬起时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Reduced tissue damage is a theoretical advantage of using an ultrasonic harmonic scalpel. We hypothesized that the harmonic scalpel would outperform electrocautery in deep inferior epigastric perforator flap surgery, possibly resulting in a shorter operative time and reduced postoperative drainage and pain. Between January and August 2015, 24 consecutive patients were assigned to immediate deep inferior epigastric perforator flap elevation (12 for bipolar electrocautery and 12 for harmonic scalpel). The main outcome variables were total operative time, flap elevation time (starting from the fascia incision), and drainage volume. We compared the number of perforators isolated and the Moon and Taylor classification of the pedicle. Data were tested for normality using the Kolmogorov-Smirnov test before analysis. Continuous variables were compared by Wilcoxon rank-sum test. Data were analyzed using the statistical software SAS, version 9.3 (SAS Institute, Cary, NC, USA). Both groups were comparable with respect to clinical characteristics (mean age, body mass index, and flap weights). There was a statistically significant difference in the operative time between dissection with the harmonic scalpel and electrocautery (305.2 vs. 380.3 min, respectively, p = 0.002). The flap elevation time was reduced, particularly when using the harmonic scalpel where its usage seems crucial for dissecting deep inferior epigastric perforators (59.8 vs. 145.9 min, respectively, p < 0.0001). No statistical difference was observed in the drainage volume and length of hospital stay between the groups. We conclude that the harmonic scalpel may be more reliable and efficient as an alternative to electrocautery.
引用
- Lee YJ, Kim HY, Han HH, et al. Comparison of dissection with harmonic scalpel and conventional bipolar electrocautery in deep inferior epigastric perforator flap surgery: A consecutive cohort study. J Plast Reconstr Aesthet Surg. 2016. PMID: 28017260. doi:10.1016/j.bjps.2016.11.005