文献速递乳房整形与再造创面修复

吲哚菁绿血管造影评估乳房切除术后皮瓣皮肤活力的诊断准确性:系统综述与荟萃分析

Systematic review and meta-analysis on the diagnostic accuracy of indocyanine green angiography for skin viability assessment: Evaluation in post-mastectomy flaps.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-09-17

绝对灌注截断值合并敏感度85.1%、特异度61.4%、AUC 0.77;相对灌注合并敏感度68.4%、特异度69.1%、AUC 0.74,阴性预测值高(94.7-97.1%),阳性预测值低(21.3%)。

要点

  • ICGA对乳房切除术后皮瓣皮肤活力评估具中等诊断准确性。
  • 绝对灌注截断值18.3,相对灌注截断值31.7%。
  • 高阴性预测值(94.7-97.1%)有助于排除坏死风险,阳性预测值低需谨慎。

核心结论

  • ICGA对乳房切除术后皮瓣皮肤活力评估显示中等诊断准确性,其他部位和术式的诊断性能尚待确立。

主要发现

  • 绝对灌注截断值(6项研究)合并敏感度85.1%(95%CI: 61.9-95.2%),特异度61.4%(95%CI: 43.2-77.0%),AUC 0.77。
  • 相对灌注(5项研究)合并敏感度68.4%(95%CI: 32.2-90.8%),特异度69.1%(95%CI: 45.2-85.8%),AUC 0.74。
  • 在坏死率10.9%时,合并阴性预测值94.7-97.1%,阳性预测值21.3%。

关键数值与推荐

  • 绝对灌注截断值为18.3,相对灌注截断值为31.7%。

临床怎么用

  • ICGA可用于乳房切除术后皮瓣皮肤活力评估,高阴性预测值有助于排除坏死风险,但阳性预测值低,阳性结果需结合临床综合判断。

局限性

  • 所有定量合并研究均针对乳房切除术后皮瓣,其他部位和术式的诊断准确性尚未确立。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Indocyanine green angiography (ICGA) is frequently used to assess skin viability; however, there is no clear overview of its diagnostic accuracy. This systematic review and meta-analysis aimed to synthesize evidence on the diagnostic accuracy of ICGA for skin viability assessment, compare quantification methods, and identify clinically relevant cut-off values. METHODS: A literature search was conducted in the PubMed, Embase, Web of Science, and Cochrane Library databases up to October 2025. Studies were included if raw diagnostic ICGA data for skin viability assessment were retrievable. Study quality was assessed using the QUADAS-2 tool. Pooled sensitivity, specificity, predictive values, and cut-off values were identified for absolute and relative perfusion using the bivariate random-effects and multiple-threshold models. RESULTS: Twelve studies were included, of which 10 were pooled in the quantitative synthesis. All 10 studies evaluated post-mastectomy flaps. The reference standard was the postoperative clinical evaluation of skin necrosis. Using multiple-threshold analysis, the pooled sensitivity for absolute perfusion cut-offs (6 studies) was 85.1% (95% CI: 61.9-95.2%) and pooled specificity was 61.4% (95% CI: 43.2-77.0%), with an area under the curve (AUC) of 0.77. For relative perfusion (5 studies), the pooled sensitivity was 68.4% (95% CI: 32.2-90.8%) and pooled specificity was 69.1% (95% CI: 45.2-85.8%), with an AUC of 0.74. The pooled negative predictive value was high (94.7-97.1%), whereas the pooled positive predictive value was low (21.3%) at the observed necrosis rate of 10.9%. The identified cut-off values were 18.3 for absolute perfusion and 31.7% for relative perfusion. CONCLUSIONS: ICGA demonstrated moderate diagnostic accuracy for assessing skin viability of post-mastectomy flaps. Its diagnostic performance for the skin in other locations and procedures is yet to be established.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. de Haan J, Neeter LMFH, Pijpe A, et al. Systematic review and meta-analysis on the diagnostic accuracy of indocyanine green angiography for skin viability assessment: Evaluation in post-mastectomy flaps. J Plast Reconstr Aesthet Surg. 2026. PMID: 42879877. doi:10.1016/j.bjps.2026.09.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。