文献速递乳房整形与再造显微修复重建

DIEP皮瓣组织氧合轨迹的近红外光谱定量分析

Quantitative analysis of tissue oxygenation trajectories in DIEP flaps using near infrared spectroscopy: A retrospective cohort study.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-10-12

本研究回顾性分析65例患者107个DIEP乳房重建皮瓣的早期术后近红外光谱数据(676,308次StO₂测量),发现StO₂呈非线性变化,大部分变异源于患者间差异(67.1%),大皮岛是皮瓣层面主要预测因素,平均StO₂显著更高(校正后+9.7个百分点,95%CI 3.5-16.0;p=0.003),而全身因素中平均动脉压和外周血氧饱和度与StO₂稳健相关。轨迹指标可区分静脉危象皮瓣与正常变异,但单纯负斜率不具特异性。

要点

  • 大皮岛是皮瓣层面StO₂的主要预测因素,校正后平均高9.7个百分点
  • 患者间变异占67.1%,全身生理参数(MAP、SpO₂)与StO₂稳健相关
  • 轨迹指标可辅助区分静脉危象,但单纯负斜率不具特异性

核心结论

  • 术后DIEP皮瓣StO₂反映皮瓣特征和全身生理状态,小皮岛可能模仿静脉危象。
  • 结合轨迹特征与生理数据或可提高对真实血管危象的鉴别能力。

研究设计与样本

  • 回顾性队列研究,分析65例患者107个DIEP乳房重建皮瓣的早期术后NIRS数据。
  • 共纳入676,308次连续StO₂测量(ViOptix),采用线性混合效应模型分析非线性时间效应及固定效应。

主要发现

  • StO₂呈非线性术后变化,大部分变异源于患者间差异(67.1%)。
  • 大皮岛是皮瓣层面主要预测因素,校正后平均StO₂高9.7个百分点(95%CI 3.5-16.0;p=0.003),稳健于不同估计方法。
  • 耦合器直径、动静脉吻合数量及皮瓣重量与StO₂无关联。
  • 平均动脉压和外周血氧饱和度与StO₂稳健相关,体温和心率在自相关校正后不显著。
  • 双侧监测皮瓣在患者间存在差异(中位数4.9个百分点),轨迹指标可将2个静脉危象皮瓣与正常变异区分,但单纯负斜率不具特异性。

临床怎么用

  • 临床解读DIEP皮瓣StO₂时需考虑皮岛大小及全身血流动力学参数。
  • 小皮岛患者StO₂偏低不一定提示静脉危象,应结合轨迹特征与生理数据综合判断。

局限性

  • 回顾性研究设计。
  • 仅分析早期术后数据,样本来自单一中心。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Near-infrared spectroscopy (NIRS) is an adjunct for monitoring breast free flaps. However, there is a paucity of studies using large NIRS datasets to characterize how patient-, flap-, and operative-level factors and systemic hemodynamics influence postoperative tissue oxygen saturation (StO2). METHODS: In this retrospective study, we analyzed early postoperative NIRS data from DIEP-based breast reconstructions, comprising >676,000 continuous StO₂ measurements from an exteriorized skin paddle (ViOptix). Trajectories were analyzed using linear mixed-effects models with nonlinear time effects and fixed effects for patient-, flap-, and operative-level variables. Trajectory metrics (desaturation burden, variability, and overall slope) were calculated. A separate model examined the associations with matched vital signs. RESULTS: Overall, 107 flaps in 65 patients (676,308 measurements) were analyzed. StO₂ followed a non-linear postoperative course, and most variance was between the patients (67.1%) rather than within flaps. Large skin paddles were the dominant flap-level predictor, with significantly higher mean StO₂ (adjusted +9.7% points, 95% CI 3.5-16.0; p=0.003, robust across estimators), whereas coupler diameter, arterial and venous anastomosis counts, and flap weight showed no association. Among the systemic factors, higher mean arterial pressure and peripheral oxygen saturation were robustly associated with higher StO₂, whereas temperature and heart rate did not survive autocorrelation correction. Bilaterally monitored flaps diverged among the patients (median 4.9 points). Trajectory metrics separated the two venous-failure flaps from normal variation, though negative slope alone was non-specific. CONCLUSIONS: Postoperative DIEP flap StO₂ reflects flap characteristics and systemic physiology; small skin paddles may mimic venous compromise. Combining trajectory features with physiologic data may improve discrimination of true vascular compromise.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Kauke-Navarro M, Moscarelli JR, Kong V, et al. Quantitative analysis of tissue oxygenation trajectories in DIEP flaps using near infrared spectroscopy: A retrospective cohort study. J Plast Reconstr Aesthet Surg. 2026. PMID: 42925714. doi:10.1016/j.bjps.2026.10.012