文献速递显微修复重建创面修复

聚左旋乳酸袖套管辅助微血管吻合的有效性、效率与安全性

Efficacy, Efficiency, and Safety of a Poly-L-lactic Acid Cuff Tube Assisting for Microvascular Anastomosis.
PubMed 文献 · Plast Reconstr Surg · 2026-10-12

本研究在体外评估聚左旋乳酸(PLLA)袖套管的生物相容性,并在大鼠同基因原位后肢移植模型中验证其无缝合袖套吻合技术的可行性。结果显示PLLA袖套管无细胞毒性,单血管吻合平均时间18.9分钟,短于手工缝合的28.8分钟,袖套管组血管全部通畅而手工缝合组出现3例完全闭塞,组织病理学未见明显炎症或免疫反应。

要点

  • PLLA袖套管无细胞毒性,大鼠模型中未见明显炎症或免疫反应。
  • 袖套管法单血管吻合平均18.9分钟,短于手工缝合的28.8分钟。
  • 袖套管组血管全部通畅,手工缝合组出现3例完全闭塞。

核心结论

  • PLLA袖套管是传统手工缝合的安全有效替代方案,在微血管吻合中具有较强临床应用潜力。

研究设计与样本

  • 体外评估PLLA袖套管生物相容性,采用L929细胞活力检测和哺乳动物染色体畸变试验。
  • 体内采用大鼠同基因原位后肢移植模型验证无缝合袖套吻合技术的手术可行性。

主要发现

  • L929细胞活力检测和哺乳动物染色体畸变试验均显示PLLA袖套管无细胞毒性。
  • 袖套管法单血管吻合平均时间为18.9分钟,手工缝合法为28.8分钟。
  • 袖套管组所有血管保持通畅,手工缝合组发生3例完全闭塞。
  • 组织病理学分析显示PLLA袖套管植入未见明显炎症或免疫反应迹象。

临床怎么用

  • 在微血管吻合中可考虑采用PLLA袖套管无缝合技术以缩短吻合时间并维持血管通畅。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Vascular anastomosis is a cornerstone of microsurgery. Anastomosis time and vessel patency significantly influence surgical success. The disadvantages of the traditional hand-sewn method requires a high technical threshold, prolonged surgical time, and an increased risk of vessel occlusion or leakage. Consequently, developing a reliable device to facilitate vascular anastomosis is essential in microsurgery. METHODS: In this study, a poly-L-lactic acid (PLLA) cuff tube with favorable mechanical and biological properties was employed for anastomosis using a nonsuture cuff technique. Its biocompatibility was comprehensively evaluated in vitro. Its surgical feasibility was validated in vivo using a rat syngeneic orthotopic hindlimb transplantation model. Vessel patency and anastomotic time were documented, and histopathological analysis was performed. RESULTS: Both L929 cells viability assay and mammalian chromosomal aberration test showed that the PLLA cuff tubes were noncytotoxic. The mean time of anastomosing a single vessel was 18.9 min using the cuff tube compared with 28.8 min using the hand-sewn method. All vessels remained patent in the cuff technique group, while 3 cases of total occlusion occurred in the hand-sewn group. Histopathological analysis revealed no obvious signs of inflammation or immune response associated with PLLA cuff tube implantation. CONCLUSIONS: PLLA cuff tube is a safe and effective alternative to traditional hand-sewn method, with strong potential for clinical application in microvascular anastomosis.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Qiu Y, Su H, Luo J, et al. Efficacy, Efficiency, and Safety of a Poly-L-lactic Acid Cuff Tube Assisting for Microvascular Anastomosis. Plast Reconstr Surg. 2026. PMID: 42862102. doi:10.1097/PRS.0000000000013523

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。