烧伤患者1分钟坐立试验的信效度:6分钟步行试验的替代方案
本研究纳入40例烧伤患者,在入院和出院时分别进行1分钟坐立试验(1-STST)和6分钟步行试验(6-MWT),评估1-STST的信度和效度。结果显示1-STST在入院和出院时均具有优异的重测信度(ICC=0.972和0.946),与6-MWT显著相关(r=0.842和0.813),与TBSA负相关(r=-0.568和-0.653)。结论认为1-STST是评估烧伤患者急性后期恢复期功能运动能力的有效可靠工具,可在空间和时间有限时替代6-MWT。
要点
- 1-STST在烧伤患者入院和出院时均显示优异重测信度(ICC>0.94)。
- 1-STST与6-MWT显著相关(r>0.81),与TBSA负相关(r<-0.56)。
- 1-STST可作为空间和时间有限时6-MWT的潜在替代工具。
核心结论
- 1-STST是评估烧伤患者急性后期恢复期功能运动能力的有效且可靠工具。
- 在空间和时间有限的情况下,1-STST可作为6-MWT的潜在替代工具。
研究设计与样本
- 纳入40例烧伤患者(女18例,男22例),年龄24至49岁。
- 在入院和出院时分别进行1-STST和6-MWT评估,同日完成测试,每次测试间休息30分钟。
- 采用组内相关系数(ICC)和Bland-Altman图评估信度,通过与6-MWT和TBSA的相关性分析构建效度。
主要发现
- 患者平均总烧伤面积(TBSA)为18%。
- 1-STST在入院和出院时的重测信度ICC分别为0.972和0.946(p<0.001)。
- 1-STST与6-MWT在入院和出院时均显著相关(r=0.842和r=0.813,p<0.001)。
- 1-STST与TBSA在入院和出院时均呈负相关(r=-0.568和r=-0.653,p<0.001)。
- 1-STST与6-MWT的生理反应在入院和出院时均相似(p>0.05)。
临床怎么用
- 在烧伤患者急性后期恢复期,可采用1-STST评估功能运动能力。
- 当空间或时间受限时,1-STST可替代6-MWT进行功能评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this study was to investigate the reliability and validity of the 1-minute sit-to-stand test (1-STST) in evaluating functional exercise capacity both at admission and discharge. METHODS: A total of 40 burn patients (18 females; 22 males) were included in this study. The ages of the burn patients range from 24 to 49. Functional exercise capacity in burn patients was evaluated using the 1-STST and the 6-minute walk test (6-MWT), both at admission and discharge. All patients performed the 1-STST and retest, and the 6-MWT on the same day, with a 30-minute rest break between each test. The intraclass correlation coefficient (ICC) and Bland-Altman plots were used to assess reliability. The construct validity of the 1-STST was analyzed using correlations with the 6MWT and TBSA. RESULTS: The mean total burn surface area burned (TBSA) of burn patients was 18%. When the causes of injury were examined, 17% of the patients had thermal burns, 14% had electrical burns, and 9% had flame burns. The 1-STST showed excellent test-retest reliability at admission and discharge (ICC=0.972 and 0.946, respectively; p < 0.001). The 1-STST was significantly correlated with the 6-MWT both at admission and discharge (r = 0.842; r = 0.813, respectively, p < 0.001). The 1-STST was negatively correlated with TBSA (r = -0.568; r = -0.653, respectively; p < 0.001). Physiological responses to the 1-STST and the 6-MWT were similar both at admission and discharge (p > 0.05). CONCLUSION: The 1-STST is a valid and reliable tool for assessing functional exercise capacity in patients with burn injury for post-acute recovery. 1-STST can be a potential alternative tool over 6-MWT in situations where space and time are limited.
引用
- Değirmenci ÖÖ, Seyyah M. Test-retest reliability and validity of the 1-minute sit-to-stand test in patients with burn injury: An alternative to the 6-minute walk test for post-acute recovery. Burns. 2026. PMID: 42874518. doi:10.1016/j.burns.2026.108255
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。