文献速递乳房整形与再造创面修复

引流管抗菌方案对假体乳房再造感染的影响:倾向评分匹配分析

The Impact of a Drain Antisepsis Protocol on Infection in Implant-Based Breast Reconstruction: A Propensity Score Matched Analysis.
PubMed 文献 · Plast Reconstr Surg · 2026-09-28

本研究回顾性分析1765个组织扩张器(1193例患者),比较标准化引流管抗菌方案(氯己定圆片每7天更换+每日Dakin溶液冲洗引流球)与对照组的感染率。倾向评分匹配后每组411个扩张器,抗菌组感染率11.2% vs 16.3%(p=0.033),感染相关扩张器取出率5.8% vs 10.2%(p=0.021)。

要点

  • 标准化引流管抗菌方案与即刻假体乳房再造术后感染率降低相关
  • 该方案与感染相关组织扩张器取出率降低相关
  • 方案为低成本干预,可减少术后微生物定植和感染并发症

核心结论

  • 实施标准化引流管抗菌方案与即刻组织扩张器乳房再造术后手术部位感染和装置取出减少相关。
  • 该简单、低成本的干预是减轻术后微生物定植和感染并发症的实用策略。

研究设计与样本

  • 回顾性综述,纳入接受即刻组织扩张器乳房再造的患者。
  • 共纳入1765个组织扩张器(1193例患者),抗菌组450个,对照组1315个。
  • 采用倾向评分匹配,基于合并症、手术细节和肿瘤治疗方案进行匹配。
  • 匹配后保留822个扩张器,每组411个。

主要发现

  • 抗菌组感染率低于对照组(11.2% vs 16.3%,p=0.033)。
  • 抗菌组感染相关组织扩张器取出率低于对照组(5.8% vs 10.2%,p=0.021)。

关键数值与推荐

  • 引流管抗菌方案包括:引流出口处使用氯己定圆片每7天更换一次,每日用Dakin溶液冲洗引流球,均持续至拔除引流管。

临床怎么用

  • 在即刻组织扩张器乳房再造中,可考虑采用标准化引流管抗菌方案以降低感染和装置取出风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Surgical site infection is one of the most common complications following implant-based breast reconstruction and is associated with significant morbidity and healthcare costs. Surgical drains may serve as a conduit for bacterial contamination; however, the impact of a standardized drain antisepsis protocol on clinical infection rates remains incompletely defined. This study analyzes the association between a drain antisepsis protocol and postoperative infection using a propensity score-matched analysis. METHODS: A retrospective review was performed for patients undergoing immediate breast reconstruction with a tissue expander (TE). Patients who followed a standardized drain antisepsis protocol, which included use of a chlorhexidine disc exchanged every 7 days at the drain exit site along with daily drain bulb irrigation with Dakin's solution, both until drain removal, were compared to controls. Propensity score matching was performed based on comorbidities, surgical details, and oncologic treatment plans. RESULTS: A total of 1,765 TEs (1,193 patients) were included, consisting of 450 in the drain antisepsis group and 1,315 controls. After matching, 822 expanders remained, with 411 per group. The infection rate was lower in the drain antisepsis group compared to controls (11.2% vs 16.3%, p = 0.033). The infection-related TE explantation rate was lower among patients in the drain antisepsis group (5.8% vs 10.2%, p = 0.021). CONCLUSION: Implementation of a standardized drain antisepsis protocol was associated with reduced surgical site infection and device explantation following immediate breast reconstruction with a TE. This simple, low-cost intervention is a practical strategy to mitigate postoperative microbial colonization and infectious complications.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Boydstun AG, Shay PL, Hanwright PJ, et al. The Impact of a Drain Antisepsis Protocol on Infection in Implant-Based Breast Reconstruction: A Propensity Score Matched Analysis. Plast Reconstr Surg. 2026. PMID: 42804663. doi:10.1097/PRS.0000000000013476

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。