文献速递乳房整形与再造显微修复重建

激光散斑对比成像与吲哚菁绿在乳房皮瓣活力预测中的比较

Revolutionizing Precision of Necrosis: Laser Speckle Contrast Imaging versus Indocyanine Green for Breast Flap Viability.
PubMed 文献 · Plast Reconstr Surg · 2026-07-28

本研究前瞻性纳入87例乳房切除后立即重建患者,比较激光散斑对比成像(LSCI)与吲哚菁绿(ICG)荧光成像预测皮瓣坏死的能力。LSCI灵敏度更高(87.10% vs 81.82%),术中灌注阈值为37.93%,术后为22.84%;ICG特异性更高(80.42% vs 71.60%)但仅能术中单次使用。两者均为术后皮瓣坏死的优越预测工具,LSCI可重复测量,可能作为ICG的可行替代。

要点

  • LSCI预测皮瓣坏死灵敏度87.10%,高于ICG的81.82%。
  • LSCI术中灌注阈值37.93%,术后阈值22.84%。
  • ICG特异性80.42%高于LSCI的71.60%,但仅限术中单次使用。

核心结论

  • LSCI与ICG均为术后皮瓣坏死的优越预测工具,LSCI可重复测量,可能作为ICG的可行替代。

主要发现

  • 195个测量单位中,存活与坏死皮瓣的灌注值存在显著差异。
  • LSCI灵敏度87.10%,高于ICG的81.82%。
  • ICG特异性80.42%,高于LSCI的71.60%。
  • LSCI术中灌注阈值为37.93%,术后为22.84%。
  • ICG成像仅限术中单次使用,LSCI可重复测量。

关键数值与推荐

  • LSCI灵敏度87.10%,ICG灵敏度81.82%。
  • ICG特异性80.42%,LSCI特异性71.60%。
  • LSCI术中灌注阈值37.93%,术后阈值22.84%。

临床怎么用

  • 术中及术后可使用LSCI重复评估皮瓣灌注,结合灌注阈值预测坏死风险。
  • ICG可用于术中单次评估,特异性较高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Immediate breast reconstruction helps breast cancer patients regain physical and emotional confidence, but the risk of skin flap necrosis can lead to reconstruction failure. Laser speckle contrast imaging (LSCI) has emerged as an innovative technique for predicting necrosis. This study prospectively compared the effectiveness of indocyanine green (ICG) fluorescence imaging with LSCI in predicting the risk of necrosis after direct-to-implant reconstruction. METHODS: This study included 87 patients undergoing mastectomy and immediate reconstruction from December of 2022 to January of 2024. Perfusion of the 195 measurement units, including nipple-areola complex and peri-incision skin flaps, was assessed by both LSCI and ICG imaging intraoperatively and postoperatively. RESULTS: A total of 195 measurement units were analyzed, showing significant differences in perfusion values between surviving and necrotic flaps. LSCI demonstrated superior sensitivity (87.10% versus 81.82%), with a perfusion threshold of 37.93% intraoperatively and 22.84% postoperatively. ICG imaging showed higher specificity (80.42% versus 71.60%) but was limited to a single intraoperative use. CONCLUSIONS: Both LSCI and ICG were superior predictors of postoperative flap necrosis. LSCI offers the advantage of repeated measurements, making it a versatile tool for ongoing assessment. While the 2 methods showed consistent differences in measured values, LSCI may serve as a viable alternative to ICG in evaluating tissue viability.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Liu R, Lan Y, Zhang H, et al. Revolutionizing Precision of Necrosis: Laser Speckle Contrast Imaging versus Indocyanine Green for Breast Flap Viability. Plast Reconstr Surg. 2026. PMID: 42519935. doi:10.1097/PRS.0000000000012685

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。