文献速递乳房整形与再造显微修复重建

DIEP皮瓣乳房重建术后脂肪坏死:系统综述与荟萃分析

"Fat necrosis following deep inferior epigastric artery perforator flap breast reconstruction: A systematic review and meta-analysis".
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-07-20

该系统综述与荟萃分析纳入100项研究(9704个皮瓣),评估DIEP皮瓣乳房重建术后脂肪坏死的预测因素。结果显示术中ICG荧光、外侧行穿支、≥2穿支及SIEV静脉增压可降低风险,而单侧重建和BMI≥25增加风险。术前CTA与脂肪坏死无显著关联。

要点

  • 术中ICG荧光、外侧行穿支、≥2穿支及SIEV静脉增压可降低脂肪坏死风险。
  • 单侧重建和BMI≥25与脂肪坏死风险升高相关。
  • 术前CTA与脂肪坏死无显著关联,不推荐仅为此常规使用。

核心结论

  • 优化穿支选择、使用术中ICG灌注 mapping 及SIEV吻合静脉增压可减少DIEP皮瓣脂肪坏死。

研究设计与样本

  • 共纳入100项研究,其中42项符合荟萃分析条件,代表9704个皮瓣。

主要发现

  • 术中ICG荧光降低脂肪坏死风险(RR 0.64,95% CI 0.49-0.83,P=0.0008)。
  • 外侧行穿支较内侧+外侧行穿支降低风险(RR 0.59,95% CI 0.43-0.82,P=0.001)。
  • 获取≥2穿支降低风险(RR 0.68,95% CI 0.48-0.96,P=0.03)。
  • SIEV静脉增压降低风险(RR 0.48,95% CI 0.28-0.84,P=0.010)。
  • 单侧重建增加风险(RR 1.53,95% CI 1.13-2.06,P=0.006);BMI≥25增加风险(RR 1.60,95% CI 1.05-2.43,P=0.03)。

关键数值与推荐

  • 术中ICG荧光、外侧行穿支、≥2穿支及SIEV静脉增压为保护因素。
  • 单侧重建和BMI≥25为危险因素。
  • 术前CTA与脂肪坏死无显著关联(RR 0.60,95% CI 0.33-1.11,P=0.10)。

临床怎么用

  • 优先选择外侧行穿支并获取至少2支穿支。
  • 术中常规使用ICG荧光评估灌注。
  • 考虑SIEV吻合以增强静脉回流。
  • 对BMI≥25或单侧重建患者应告知脂肪坏死风险升高。

局限性

  • 原文未报告具体局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Fat necrosis has been described to affect up to 35.0% of Deep Inferior Epigastric Artery Perforator (DIEP) flap breast reconstructions. It compromises esthetic outcomes and can falsely raise concerns about cancer recurrence. This study aims to identify factors predictive of postoperative fat necrosis in reconstructed breast flaps. METHODS: Following PRISMA 2020 guidelines, MEDLINE/EMBASE/CINAHL/CENTRAL databases were searched through December 4, 2024, for studies reporting the incidence of postoperative fat necrosis in DIEP flaps. Meta-analyzes were performed for variables supported by at least four comparative studies. Fixed- and random-effects models were applied to pool risk ratios (RRs) with 95% confidence intervals (CIs), using an I² heterogeneity threshold of 50%. RESULTS: The systematic review (SR) included 100 studies (42 eligible for meta-analyzes), representing 9704 flaps. Fat necrosis risk was reduced with intraoperative indocyanine green (ICG) fluorescence (RR 0.64, 95% CI 0.49-0.83, P=0.0008), flaps based on lateral row perforators versus medial and lateral (RR 0.59, 95% CI 0.43-0.82, P=0.001), harvesting ≥2 perforators (RR 0.68, 95% CI 0.48-0.96, P=0.03), and venous outflow augmentation with the Superficial Inferior Epigastric Vein (SIEV) (RR 0.48, 95% CI 0.28-0.84, P=0.010). Fat necrosis risk increased with unilateral versus bilateral reconstructions (RR 1.53, 95% CI 1.13-2.06, P=0.006) and BMI ≥25 (RR 1.60, 95% CI 1.05-2.43, P=0.03). Preoperative CT angiogram was not significantly associated with fat necrosis (RR 0.60, 95% CI 0.33-1.11, P=0.10). CONCLUSIONS: To minimize fat necrosis, surgeons should optimize perforator selection, use intraoperative ICG perfusion mapping, and augment venous outflow with SIEV anastomosis. Patients with elevated BMI or unilateral reconstructions should be counseled regarding their increased risk.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Raman KS, Akdag A, Morel SBA, et al. "Fat necrosis following deep inferior epigastric artery perforator flap breast reconstruction: A systematic review and meta-analysis". J Plast Reconstr Aesthet Surg. 2026. PMID: 42501419. doi:10.1016/j.bjps.2026.07.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。