文献速递乳房整形与再造显微修复重建

PAP皮瓣乳房再造的最佳受区血管:解剖学研究

Determining the best recipient vessel site for autologous microsurgical breast reconstruction using PAP flaps: An anatomical study.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-07-17

基于50具新鲜女性尸体、100次解剖,测量PAP皮瓣与胸廓内、胸背、旋肩胛血管的直径匹配。结果显示动脉以胸背血管与PAP匹配最佳,静脉以旋肩胛静脉与PAP匹配最佳,支持胸背动脉和旋肩胛静脉作为首选受区血管。

要点

  • PAP皮瓣动脉与胸背动脉完美匹配显著多于旋肩胛动脉(p=0.037)。
  • PAP皮瓣静脉与旋肩胛静脉完美匹配显著多于胸廓内静脉(p=0.0088)。
  • 解剖学上首选受区血管为胸背动脉和旋肩胛静脉。

核心结论

  • 本研究支持胸背动脉和旋肩胛静脉作为PAP皮瓣乳房再造的首选受区血管,因其与供区血管直径最匹配。

研究设计与样本

  • 解剖学观察性研究,对50具新鲜女性尸体双侧共100次解剖,测量三个受区血管区域。
  • 血管内径使用刻度1.0至5.0mm、间隔0.5mm的血管测量器测量。

主要发现

  • PAP动脉、胸廓内动脉、旋肩胛动脉、胸背动脉中位直径分别为2.0、2.5、2.5、2.0mm。
  • PAP静脉、胸廓内静脉、旋肩胛静脉、胸背静脉中位直径分别为3.0、2.5、3.0、2.5mm。
  • 个体水平上,PAP与胸背动脉完美匹配显著多于PAP与旋肩胛动脉(p=0.037)。
  • 静脉系统中,PAP与旋肩胛静脉完美匹配显著多于PAP与胸廓内静脉(p=0.0088)。
  • PAP与胸廓内动脉相比PAP与胸背动脉或旋肩胛动脉无显著差异;静脉其他比较无显著差异。

临床怎么用

  • 在PAP皮瓣乳房再造中,可优先选择胸背动脉和旋肩胛静脉作为受区血管。
  • 术前或术中可根据血管直径匹配情况选择受区,胸背动脉和旋肩胛静脉解剖上匹配最佳。

局限性

  • 本研究为尸体解剖研究,未报告活体血流动力学或临床结局数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Since its first description in 2012, the profunda femoris artery perforator (PAP) flap has gained increasing popularity and has progressively become the second-line option for autologous breast reconstruction. As with the deep inferior epigastric artery perforator (DIEP) flap, several recipient vascular pedicles, including the internal thoracic, thoracodorsal, and circumflex scapular pedicles, have been described for microvascular anastomoses. The aim of this anatomical observational study was to identify the optimal recipient site for PAP flap by determining the best donor-recipient vessel diameter match among these three potential pedicles. METHODS: This study was based on 100 dissections of the three anatomical regions of interest, performed bilaterally in 50 fresh female cadavers. The internal vessel diameters were measured using a vascular gauge ranging from 1.0 to 5.0 mm, with successive 0.5-mm graduations. RESULTS: The median diameter of the PAP, internal thoracic (ITA), circumflex scapular (CSA) and thoracodorsal (TDA) arteries were: 2.0, 2.5, 2.5, and 2.0 mm, respectively. The median diameter of profunda femoris pedicle perforator (PVP), internal thoracic (ITV), circumflex scapular (CSV), and thoracodorsal (TDV) veins were: 3.0, 2.5, 3.0, and 2.5 mm, respectively. At the individual level, a perfect match between PAP and TDA was significantly more frequent than between PAP and CSA (p = 0.037), whereas no significant difference was observed between PAP and ITA compared with either PAP and TDA or PAP and CSA. For the venous system, a perfect match between PVP and CSV was significantly more frequent than that between PVP and ITV (p= 0.0088); however, no significant differences were found between PVP and ITV compared with PVP and TDV or between PVP and CSV compared with PVP and TDV. CONCLUSIONS: This study supports the thoracodorsal artery and circumflex scapular veins as the preferred recipient vessels, which, from an anatomical standpoint, provide the closest diameter match with the donor pedicles.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Lhuaire M, Sedbon T, Biau D, et al. Determining the best recipient vessel site for autologous microsurgical breast reconstruction using PAP flaps: An anatomical study. J Plast Reconstr Aesthet Surg. 2026. PMID: 42501421. doi:10.1016/j.bjps.2026.07.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。