该回顾性队列研究纳入四年间932例游离皮瓣,其中302例术后联合使用Masimo O3近红外光谱(NIRS)监测。NIRS监测组再探查后挽救率更高、完全坏死率更低,NIRS趋势变化预测皮瓣危象的ROC曲线表现良好,局部氧饱和度下降22.5%为检测早期血管危象的最佳阈值。

要点

  • NIRS辅助监测与再探查后更高挽救率和更低完全皮瓣失败率相关。
  • 局部氧饱和度下降22.5%是检测早期血管危象的最佳阈值。
  • NIRS趋势变化对皮瓣危象具有良好区分能力,支持作为术后监测辅助手段。

核心结论

  • NIRS作为游离皮瓣术后辅助监测手段可靠,并提供客观阈值辅助临床决策。

研究设计与样本

  • 回顾性队列研究,纳入四年间单中心932例游离皮瓣,其中302例术后联合NIRS监测。

主要发现

  • 总体再探查率为7.9%。
  • NIRS监测组再探查后挽救率更高、完全皮瓣失败率更低。
  • NIRS趋势变化预测皮瓣危象的ROC曲线区分能力良好。
  • 局部氧饱和度下降22.5%为检测早期血管危象的最佳阈值。

关键数值与推荐

  • 局部氧饱和度下降22.5%作为检测早期血管危象的最佳阈值。

临床怎么用

  • 可将NIRS作为游离皮瓣术后辅助监测手段,并以局部氧饱和度下降22.5%作为预警参考阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Free flap failure secondary to microvascular thrombosis remains a significant complication in reconstructive surgery, and timely detection of vascular compromise is critical to maximize salvage. This retrospective cohort study evaluated 932 free flaps performed over a four-year period at a tertiary center, of which 302 were monitored postoperatively using Masimo's O3 ® Regional Oximetry system's near-infrared spectroscopy (NIRS) device in addition to standard clinical assessment. Primary outcomes included re-exploration, complete flap failure, and salvage following take-back. The overall re-exploration rate was 7.9%. Flaps monitored with NIRS demonstrated higher salvage rates following re-exploration and lower complete flap failure rates compared with clinical monitoring alone. Use of NIRS during the index reconstruction was independently associated with improved flap survival. Receiver operating characteristic analysis demonstrated good discriminative performance of NIRS trend changes for predicting flap compromise, and a 22.5% reduction in regional oxygen saturation was identified as the optimal threshold for detecting early vascular compromise. These findings support the use of adjunctive NIRS surveillance as a reliable modality for postoperative free flap monitoring and provide an objective threshold to assist clinical decision-making.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Neo SZJ, Yen YH, Lee ASH, et al. Clinical Validation of Near Infrared Spectroscopy for Free Flap Monitoring and Establishing Intervention Thresholds Using the Masimo O3 Device. Ann Plast Surg. 2026. PMID: 42497025. doi:10.1097/SAP.0000000000004827

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。