Nd:YAG激光致小鼠皮肤损伤:建立激光烧伤动物模型的初步研究
本研究以Q开关Nd:YAG激光(能量密度12 J/cm²、光斑3 mm)照射麻醉小鼠背部皮肤5、10、15、30秒,72小时后取材行组织学评估。结果显示损伤呈时间依赖性加重:5和10秒致一度烧伤,15和30秒出现胶原紊乱、表皮剥离及凝固性坏死。该模型在2只小鼠中可重复,为激光皮肤损伤的定量与治疗研究奠定基础。
要点
- Q开关Nd:YAG激光12 J/cm²照射小鼠皮肤可建立可重复的烧伤模型。
- 5–10秒暴露致一度烧伤,15–30秒致进行性胶原紊乱与凝固性坏死。
- Masson三色染色显示随暴露时间延长热性胶原硬化与结构丢失加重。
核心结论
- Q开关Nd:YAG激光照射小鼠皮肤可产生时间依赖性组织学损伤 continuum,并建立可重复的皮肤定向能损伤小鼠模型。
研究设计与样本
- 初步动物实验:麻醉小鼠背部皮肤接受Q开关Nd:YAG激光照射,固定能量密度12 J/cm²、光斑3 mm,暴露时间5、10、15、30秒,72小时后取材行组织学评估。
- 组织学评估指标包括胶原完整性、表皮结构、血管变化、炎症浸润及附件结构保存。
- 结果在2只小鼠中可重复。
主要发现
- 5和10秒暴露产生一度烧伤,伴一定程度表皮破坏但真皮层完整。
- 15和30秒暴露导致进行性胶原紊乱、表皮剥离、附件与血管损伤,最终出现凝固性坏死。
- Masson三色染色显示随激光作用时间延长,热性胶原硬化与胶原结构丢失加重。
临床怎么用
- 该模型可用于后续激光皮肤损伤的定量研究与治疗干预研究。
局限性
- 为初步研究,仅定性描述组织学反应,样本量小(2只小鼠可重复),未进行定量分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Directed-energy sources such as Q-switched Nd:YAG lasers are widely used in clinical, cosmetic, and military settings, yet no standardized animal model exists for cutaneous laser burn injury. This pilot study aims to establish a reproducible murine laser burn model and qualitatively characterize the progressive histologic severity in cutaneous injury associated with increasing laser exposure duration. METHODS: Laser burns were created on the back skin of anesthetized mice using a Q-switched Nd:YAG laser at a fixed fluence (12 J/cm 2 ) and spot size (3 mm), with exposure times of 5, 10, 15, and 30 seconds (s). Skin specimens were harvested 72 hours after laser application and evaluated histologically for collagen integrity, epidermal architecture, vascular changes, inflammatory infiltration, and adnexal structure preservation. RESULTS: Laser exposure induced a time-dependent continuum of injury. Early exposures (5 and 10 s) produced first-degree burn injury with some degree of epidermal disruption and intact dermal layer. In contrast, longer exposures (15 and 30 s) resulted in progressive collagen disorganization, epidermal detachment, adnexal and vascular injury, and eventual coagulative necrosis. Masson trichrome staining revealed increasing thermal stiffening and loss of collagen structure with longer laser application, highlighting progressive cutaneous injury. These findings were consistently reproduced in 2 mice. CONCLUSION: This pilot study qualitatively characterizes the histologic response of skin to Nd:YAG laser exposure and establishes a reproducible murine model for cutaneous directed-energy injury, providing a foundation for future quantitative and therapeutic studies.
引用
- Gutama B, Cornely RM, Giannas E, et al. Cutaneous Injuries From an Nd:YAG Laser Directed-Energy Source Utilizing a Murine Model: A Pilot Study for Establishing a Laser Burn Murine Model. Ann Plast Surg. 2026. PMID: 42407053. doi:10.1097/SAP.0000000000004811
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。