文献速递乳房整形与再造美容整形

聚氨酯涂层假体乳房初升级五年患者报告结局及专用量表初步验证

Five-year Patient-reported Outcomes Following Primary Breast Augmentation With Polyurethane-coated Implants: Development and Preliminary Validation of a Device-specific Instrument.
PubMed 文献 · Aesthet Surg J · 2026-06-26

PU-PRO量表感知81.3±12.8、美学满意84.5±11.9、术后体验78.2±14.3,仅1例报告波纹,无翻修手术。量表信效度初步良好。

要点

  • 聚氨酯涂层假体五年患者报告满意度持续较高。
  • PU-PRO量表三因子结构解释68%方差,信度良好。
  • 随访期内仅1例临床波纹,无翻修手术。

核心结论

  • 聚氨酯涂层假体初升级五年随访患者报告满意度持续较高,PU-PRO量表初步显示信度与结构效度。

研究设计与样本

  • 回顾性队列研究,纳入110例连续接受聚氨酯涂层假体初次美容性乳房增大患者,平均随访5.2±0.8年。

主要发现

  • PU-PRO各领域均分(0-100分):感知81.3±12.8,美学满意84.5±11.9,术后体验78.2±14.3。
  • 1例(1%)报告临床可见波纹,随访期间无翻修手术。
  • Cronbach's alpha各领域0.84-0.91,ICC 0.88-0.93,探索性因子分析三因子结构解释68%总方差。

关键数值与推荐

  • PU-PRO为15条目量表,评估感知、美学满意和术后体验三个领域。
  • 重测信度评估间隔8个月,采用组内相关系数(ICC)。

临床怎么用

  • 聚氨酯涂层假体初升级可参考本队列五年患者报告结局进行术前咨询。
  • PU-PRO量表可试用于设备特异性患者感知评估,但需进一步前瞻性验证。

局限性

  • 回顾性队列设计,未设对照组或与经验证通用量表比较。
  • 样本量有限,PU-PRO仅为初步验证,需前瞻性研究进一步确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Long-term patient-reported outcomes after primary aesthetic breast augmentation remain incompletely characterized, particularly in cohorts receiving polyurethane-coated implants. Although validated generic instruments are widely used, device-specific patient perception may not be fully captured by broader outcome measures. OBJECTIVES: To evaluate five-year patient-reported outcomes following primary breast augmentation with polyurethane-coated implants and to develop and preliminarily validate a device-specific patient-reported outcome instrument. METHODS: A retrospective cohort study was conducted including 110 consecutive patients who underwent primary aesthetic breast augmentation with polyurethane-coated implants. At a mean follow-up of 5.2 ± 0.8 years, patients completed a 15-item polyurethane implant-specific patient-reported outcome instrument (PU-PRO) assessing Perception, Aesthetic Satisfaction, and Postoperative Experience. Psychometric evaluation included content validity assessment, internal consistency analysis, exploratory factor analysis, and test-retest reliability over an 8-month interval using intraclass correlation coefficients (ICC). RESULTS: Ninety-nine patients (90%) completed the 5-year assessment, and 87 (88%) completed the 8-month reassessment. Mean scores (0-100 scale) were 81.3 ± 12.8 for Perception, 84.5 ± 11.9 for Satisfaction, and 78.2 ± 14.3 for Experience. One patient (1%) reported clinically evident rippling, and no revision surgeries occurred during follow-up. Cronbach's alpha ranged from 0.84 to 0.91 across domains. Exploratory factor analysis supported a three-factor structure explaining 68% of total variance. ICC values ranged from 0.88 to 0.93, demonstrating high temporal stability. CONCLUSIONS: Primary breast augmentation with polyurethane-coated implants demonstrated sustained high levels of patient-reported satisfaction at five-year follow-up in this cohort. The PU-PRO instrument showed preliminary evidence of reliability and construct validity. Further prospective studies incorporating validated comparative instruments are warranted.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Burciaga Soto S, Rendón Mejía NA. Five-year Patient-reported Outcomes Following Primary Breast Augmentation With Polyurethane-coated Implants: Development and Preliminary Validation of a Device-specific Instrument. Aesthet Surg J. 2026. PMID: 42360807. doi:10.1093/asj/sjag129

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。