文献速递乳房整形与再造

乳房再造在线患者教育材料的可读性、质量、可用性与文化代表性:系统综述与Meta分析

Online patient education in breast reconstruction: A systematic review and meta-analysis of readability, quality, usability, and cultural representation.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-05-20

该系统综述与Meta分析遵循PRISMA指南,检索PubMed、Embase和Scopus至2025年4月,纳入20项研究共1634份在线材料(1038个网站和596个视频)。Meta分析显示材料平均FKGL为12.68、SMOG为12.29、FRES为42.39,提示阅读难度达大学水平;DISCERN质量均分2.72/5,PEMAT可理解性61.9%、可操作性21.9%。结论认为乳房再造在线患者教育材料常难以获取、内容不完整且可操作性不足。

要点

  • 乳房再造在线材料阅读难度普遍偏高,FKGL均值为12.68、SMOG为12.29。
  • DISCERN质量均分仅2.72/5,PEMAT可操作性仅21.9%,质量与可用性不足。
  • 学术或机构来源材料优于患者生成和AI材料,但仍未达推荐标准。

核心结论

  • 乳房再造在线患者教育材料常难以获取、内容不完整且可操作性不足,亟需协调的循证指南改善数字患者教育。

研究设计与样本

  • 遵循PRISMA指南的系统综述与Meta分析,检索PubMed、Embase和Scopus至2025年4月,纳入20项研究共1634份在线材料(1038个网站和596个视频),采用随机效应模型合并数据。

主要发现

  • Meta分析显示材料阅读难度高:FKGL均值12.68、SMOG 12.29、FRES 42.39,均提示文本难度达大学水平。
  • DISCERN质量评分平均2.72/5,不同来源间变异较大。
  • PEMAT评分显示可用性欠佳:可理解性61.9%、可操作性21.9%。
  • 主题分析揭示风险披露、引用使用、语言可及性和种族/民族代表性存在不足,非英语材料和社交媒体内容的文化敏感性与深度尤为有限。
  • 学术或机构来源内容通常优于患者生成和AI生成材料,但仍未达推荐标准。

关键数值与推荐

  • 可读性评估采用FKGL、FRES和SMOG;质量评估采用DISCERN;可用性评估采用PEMAT。
  • FKGL均值12.68、SMOG 12.29、FRES 42.39,均指示文本难度达大学水平。
  • DISCERN质量评分平均2.72/5。
  • PEMAT可理解性61.9%、可操作性21.9%。

临床怎么用

  • 临床向患者推荐乳房再造在线材料时,应评估其阅读难度、质量与可操作性,优先选择学术或机构来源内容。
  • 需关注非英语材料和社交媒体内容在文化敏感性与深度上的局限,避免将其作为唯一信息来源。

局限性

  • 仅纳入定量数据研究进行Meta分析,缺乏定量数据的研究仅作主题综合。
  • 纳入研究间DISCERN质量评分变异较大。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Online patient education materials (OPEMs) are increasingly relied upon by patients seeking information on breast reconstruction. However, the readability, quality, and cultural inclusivity of these resources remain unclear. METHODS: Following PRISMA guidelines, a systematic review and meta-analysis of OPEMs related to breast reconstruction was conducted across PubMed, Embase, and Scopus through April 2025. Eligible studies evaluated websites, videos, or AI-generated materials for readability [Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Scores (FRES), and SMOG], quality (DISCERN), or usability [Patient Education Materials Assessment Tool (PEMAT)]. Data were pooled using random-effects models. Studies lacking quantitative data were synthesized thematically. RESULTS: Twenty studies encompassing 1634 OPEMs (1038 websites and 596 videos) were included. Meta-analyses revealed that most materials required a high reading level: FKGL mean=12.68, SMOG=12.29, and FRES=42.39, all indicating difficult-to-college-level text. DISCERN quality scores averaged 2.72/5, with wide variability across sources. PEMAT scores indicated suboptimal usability: understandability=61.9% and actionability=21.9%. Thematic analysis highlighted deficiencies in risk disclosure, citation use, language accessibility, and racial/ethnic representation. Non-English materials and social media content were especially limited in cultural sensitivity and depth. CONCLUSIONS: OPEMs in breast reconstruction are often inaccessible, incomplete, and insufficiently actionable. Content from academic or institutional sources generally outperforms patient-generated and AI-based materials but still falls short of recommended standards. There is an urgent need for coordinated evidence-based guidelines to improve digital patient education in reconstructive surgery.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Nguyen AT, Dejenie RA, Foote K, et al. Online patient education in breast reconstruction: A systematic review and meta-analysis of readability, quality, usability, and cultural representation. J Plast Reconstr Aesthet Surg. 2026. PMID: 42241806. doi:10.1016/j.bjps.2026.05.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。