住院烧伤患者三项功能测试的效度与信度验证
该横断面研究纳入64例住院烧伤患者,评估5次坐立试验(STS_5r)、1分钟坐立试验(STS_1min)和计时起走试验(TUG)的效度、信度、测量标准误(SEM)、最小可检测变化(MDC95)及学习效应。TUG与6分钟步行试验(6MWT)呈极强相关(r=-0.90),三项测试组内和组间信度良好至优秀(ICC 0.88-0.97),MDC95为19%-23%,各测试均存在小而显著的学习效应。
要点
- TUG与6MWT极强相关,STS_5r和STS_1min与6MWT中等相关。
- 三项测试组内和组间信度良好至优秀(ICC 0.88-0.97)。
- 各测试存在小但显著的学习效应,提示需重复两次测试。
核心结论
- STS_5r、STS_1min和TUG可用于评估住院烧伤患者的功能能力,效度和信度良好。
- 各测试存在小但显著的学习效应,提示临床需进行两次测试。
- SEM和MDC值可用于临床提高测试结果的可解释性。
研究设计与样本
- 横断面研究,纳入64例住院烧伤患者。
- 由两名评估者在三个评估时点随机应用测试:同一评估者间隔1天测试两次(组内),第二评估者在第一次评估后测试一次(组间)。
- 同时进行6分钟步行试验(6MWT)和股四头肌(QF)肌力评估。
- 每个评估时点所有测试重复两次以分析学习效应。
主要发现
- TUG与6MWT呈极强相关(r=-0.90,p<0.0001)。
- STS_5r和STS_1min与6MWT呈中等相关(r=-0.55和0.60,p<0.0001)。
- TUG与QF肌力呈中等相关(r=-0.41,p=0.0008),STS_5r和STS_1min与QF肌力相关性较弱(r=-0.30,p=0.013;r=0.21,p=0.091)。
- 组内和组间ICC值为0.88-0.97。
- MDC95值为19%-23%。
关键数值与推荐
- TUG与6MWT相关系数r=-0.90(p<0.0001)。
- STS_5r与6MWT相关系数r=-0.55(p<0.0001),STS_1min与6MWT相关系数r=0.60(p<0.0001)。
- TUG与QF肌力相关系数r=-0.41(p=0.0008),STS_5r与QF肌力r=-0.30(p=0.013),STS_1min与QF肌力r=0.21(p=0.091)。
- 组内和组间ICC值范围0.88-0.97。
- MDC95值范围19%-23%。
临床怎么用
- 三项测试可用于住院烧伤患者功能能力的临床评估。
- 因存在学习效应,建议每次评估重复两次测试以提高准确性。
- 参考SEM和MDC值(MDC95为19%-23%)解读测试结果变化。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To study the validity, reliability, standard error of the mean (SEM), minimum detectable change (MDC95), and learning effect of three functional capacity tests in hospitalized burn victims: 5-repetition Sit-to-Stand (STS_5r), 1-minute Sit-to-Stand (STS_1min) and Timed up-and-go (TUG). METHODS: In a cross-sectional study, 64 subjects were evaluated. The tests were randomly applied by two evaluators in three assessment moments: twice by the same evaluator (intra-rater) with a 1-day interval; and once by a second evaluator after the first assessment (inter-rater). 6-minute walk test (6MWT) and assessment of quadriceps femoris (QF) muscle strength were also performed. For analysis of the learning effect, all tests were repeated two times at each assessment moment. RESULTS: The TUG showed very strong correlation with the 6MWT (r = -0.90, p < 0.0001), whereas for the STS_5r and STS_1min the correlation was moderate (r = -0.55 and 0.60, respectively; p < 0.0001). As for the QF muscle strength test, there was moderate correlation with the TUG (r = -0.41, p = 0.0008) and rather modest correlations with the STS_5r (r = -0.30, p = 0.013) and the STS_1min (r = 0.21, p = 0.091). Intraclass correlation coefficient values were good to excellent in all intra- and inter-rater tests (0.88-0.97). MDC95 values ranged from 19% to 23%. Moreover, a small but statistically significant learning effect was observed in all tests. CONCLUSIONS: The STS_5r, STS_1min and TUG tests are valid and reliable to assess functional capacity of hospitalized burn victims, despite a small learning effect indicating the need to perform two tests. SEM and MDC values here described can be used in clinical practice to improve interpretability of the tests' results.
引用
- Hoshino AA, Morita AA, Travensolo CF, et al. Validation and reliability of three functional tests in hospitalized burned subjects. Burns. 2026. PMID: 42296604. doi:10.1016/j.burns.2026.108084
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。