文献速递烧伤创面修复

CytoSorb血液吸附清除烧伤脓毒症相关急性肾损伤患者革兰阴性菌群体感应分子

CytoSorb in burn patients with septic shock and acute kidney injury on continuous kidney replacement therapy efficiently reduces the levels of Gram-negative-derived quorum-sensing molecules associated with lactate increases.
PubMed 文献 · Burns · 2026-06-05

该观察性先导研究在12例接受连续性肾脏替代治疗和CytoSorb血液吸附的烧伤合并难治性脓毒性休克及SA-AKI患者中,检测8种革兰阴性菌群体感应分子。发现6种可检出,CytoSorb可早期显著降低C6-HSH、3-OH-C12-HSL和C7-PQS血浆浓度,而血滤器清除可忽略;基线乳酸与3-OH-C12-HSL及C7-PQS相对浓度正相关。

要点

  • 烧伤SA-AKI患者血浆可检出多种革兰阴性菌QS分子,血滤器清除可忽略。
  • CytoSorb可早期显著降低C6-HSH、3-OH-C12-HSL和C7-PQS浓度,但12h后部分反弹。
  • 基线乳酸与3-OH-C12-HSL和C7-PQS相对浓度正相关。

核心结论

  • 革兰阴性菌QS分子存在于烧伤SA-AKI患者体循环,与全身乳酸浓度相关,可被血液吸附而非血滤器清除。

研究设计与样本

  • 观察性先导研究,纳入12例烧伤合并难治性脓毒性休克及SA-AKI并接受CKRT和CytoSorb血液吸附的患者,研究23个滤罐的24小时治疗。

主要发现

  • 8种QS分子中6种可检出,3-oxo-C10/3-oxo-C12低于定量下限。
  • CytoSorb对C6-HSH、3-OH-C12-HSL和C7-PQS有显著早期清除,血滤器清除率<4 ml/min,12小时后部分反弹。
  • 基线乳酸与3-OH-C12-HSL相对浓度正相关(r=0.76818,p<0.002),与C7-PQS正相关(r=0.64961,p<0.03)。
  • 在部分铜绿假单胞菌血流感染患者中,上述相关性仍显著(r=0.87698,p<0.02;r=0.55547,p<0.03)。

临床怎么用

  • 对于烧伤合并SA-AKI的脓毒性休克患者,CytoSorb血液吸附可考虑用于清除革兰阴性菌QS分子,但需注意12小时后吸附饱和与反弹。

局限性

  • 样本量小(12例患者、23个滤罐),为观察性先导研究,结论需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Quorum-sensing (QS) molecules produced by Gram-negative bacteria regulate virulence and host-pathogen interactions, but their systemic role in human septic shock remains largely unexplored. We hypothesized that QS molecules are detectable in the circulation of burn patients with septic-shock-associated acute kidney injury (SA-AKI), are associated with disease severity, and are amenable to removal by extracorporeal treatment. METHODS: In this observational pilot study, plasma concentrations of eight Gram-negative-derived QS molecules were quantified by HPLC-MS/MS in 12 burn patients with refractory septic shock and SA-AKI on continuous kidney replacement therapy (CKRT) and CytoSorb hemoadsorption. Serial blood samples (0, 0.5, 6, 12, and 24 h) were collected during the 24-hour sessions of the 23 studied cartridges. QS molecule removal by the sorbent cartridge and hemofilter was assessed, and associations between baseline QS molecule levels and systemic lactate concentrations were explored. RESULTS: Out of 8 QS molecules tested, C6-homoserine lactone, 3-hydroxy-C12-HSL, C7-PQS, HQNO, HHQ, and C9-PQS were detectable in systemic plasma, whereas 3-oxo-acyl-homoserine lactones (3-oxo-C10/3-oxo-C12) were below the limit of quantification. Cytosorb induced a significant early reduction in plasma QS molecule concentrations of C6-HSH, 3-OH-C12-HSL, and C7-PQS, whereas hemofilter clearance of QS molecules was negligible (< 4 ml/min). Adsorption was followed by partial rebound at later time points, consistent with sorbent saturation and desorption after 12 h. Baseline lactate levels showed a significant positive correlation with the relative plasma concentrations of QS molecules 3-OH-C12-HSL (r = 0.76818, p < 0.002) and C7-PQS (r = 0.64961, p < 0.03), an association that remained significantly robust for both QS molecules in selected patients with Pseudomonas aeruginosa bloodstream infection (r = 0.87698, p < 0.02 and r = 0.55547, p < 0.03, respectively). CONCLUSION: Gram-negative QS molecules are detectable in the systemic circulation of burn patients with SA-AKI, are associated with systemic lactate concentrations, and can be removed by hemoadsorption but not by the hemofilter. These findings support a potential pathophysiological role of bacterial communication signals in critical illness, and a potential therapeutic target of hemoadsorption in critical illness.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Mariano F, Leporati M, Carpenito N, et al. CytoSorb in burn patients with septic shock and acute kidney injury on continuous kidney replacement therapy efficiently reduces the levels of Gram-negative-derived quorum-sensing molecules associated with lactate increases. Burns. 2026. PMID: 42296878. doi:10.1016/j.burns.2026.108105

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。