文献速递乳房整形与再造显微修复重建创面修复

SPY-PHI QP在分期乳房重建中建立预测性灌注阈值:一项前瞻性评估及硝酸甘油调整

Establishing a Predictive Perfusion Threshold Using SPY-PHI QP in Staged Breast Reconstruction: A Prospective Evaluation With Nitroglycerin Adjustment.
PubMed 文献 · Aesthet Surg J · 2026-01-01

33%阈值下预测乳房切除皮瓣坏死的敏感性87.5%、阴性预测值98.3%;排除使用硝酸甘油者后,30%阈值诊断性能最优(敏感性100%,特异性76.7%,AUC 0.8875)。结论提示未使用硝酸甘油时30%灌注阈值或可预测伤口并发症。

要点

  • SPY-PHI QP可术中定量评估乳房重建皮瓣灌注。
  • 33%阈值预测皮瓣坏死敏感性87.5%、阴性预测值98.3%。
  • 未用硝酸甘油者30%阈值敏感性100%、特异性76.7%。

核心结论

  • SPY-PHI QP可在乳房重建术中实时定量评估组织灌注。
  • 未使用硝酸甘油的患者中,30%灌注阈值或可预测伤口并发症。
  • 需更大规模前瞻性研究验证QP特异性阈值并考虑辅助干预。

研究设计与样本

  • 前瞻性评估分期乳房重建并置入组织扩张器的患者。
  • 术中使用SPY-PHI QP评估相对灌注。
  • 计算敏感性、特异性、阳性预测值、阴性预测值、准确性和比值比。
  • 亚组分析排除使用硝酸甘油 ointment 的患者以确定QP特异性截断值。

主要发现

  • 33%灌注阈值下SPY-PHI QP预测乳房切除皮瓣坏死的敏感性为87.5%,阴性预测值为98.3%。
  • 调整硝酸甘油使用后,低灌注与皮瓣坏死的关联减弱。
  • 未使用硝酸甘油的患者中,30%灌注阈值诊断性能最优:敏感性100%、特异性76.7%、曲线下面积0.8875。

关键数值与推荐

  • 33%灌注阈值:敏感性87.5%,阴性预测值98.3%(预测乳房切除皮瓣坏死)。
  • 未使用硝酸甘油者30%阈值:敏感性100%,特异性76.7%,AUC 0.8875。

临床怎么用

  • 乳房重建术中可用SPY-PHI QP定量评估皮瓣灌注。
  • 未使用硝酸甘油时,30%灌注阈值可辅助识别低灌注风险。
  • 使用硝酸甘油可能干扰灌注与坏死关联的判读。

局限性

  • 硝酸甘油使用为潜在混杂因素,需亚组分析排除。
  • 证据等级为4级(治疗性)。
  • 需更大规模前瞻性研究验证QP特异性阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The SPY Fluorescence Imaging system enables intraoperative visualization of microvascular perfusion. Recently, SPY has been integrated with Quantitative Perfusion (QP) software to provide numerical assessment of relative tissue perfusion; however, clinically actionable perfusion thresholds predictive of mastectomy skin necrosis complications have not been clearly established. OBJECTIVES: The aim of this study was to evaluate the predictive performance of proposed SPY Portable Handheld Imaging Quantitative Perfusion (PHI QP) perfusion thresholds in patients undergoing staged breast reconstruction and to explore a QP-specific cutoff while accounting for nitroglycerin ointment use as a potential confounder. METHODS: Patients undergoing staged breast reconstruction with tissue expander placement were included. SPY-PHI QP was used intraoperatively to assess relative perfusion. Diagnostic performance metrics-including sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and odds ratios-were calculated. A subanalysis excluding patients who received nitroglycerin ointment was performed to identify a QP-specific cutoff in unmanipulated tissue. RESULTS: Fifty-eight patients (83 breasts) were included. Using a 33% perfusion threshold, SPY-PHI QP demonstrated high sensitivity (87.5%) and negative predictive value (98.3%) for mastectomy skin flap necrosis. After adjusting for nitroglycerin use, the association between low perfusion and mastectomy skin flap necrosis was attenuated. In patients who did not receive nitroglycerin, a perfusion threshold of 30% demonstrated optimal diagnostic performance (sensitivity 100%, specificity 76.7%, area under the curve 0.8875). CONCLUSIONS: SPY-PHI QP provides quantitative, real-time assessment of tissue perfusion during breast reconstruction. In patients not treated with nitroglycerin, a 30% perfusion threshold may be predictive of wound complications. These findings support further investigation of QP-specific thresholds in larger, prospective studies that account for adjunctive interventions. LEVEL OF EVIDENCE: 4 (THERAPEUTIC): For image description, please refer to the figure legend and surrounding text.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Rezania N, Harmon KA, La-Anyane O, et al. Establishing a Predictive Perfusion Threshold Using SPY-PHI QP in Staged Breast Reconstruction: A Prospective Evaluation With Nitroglycerin Adjustment. Aesthet Surg J. 2026. PMID: 42161886. doi:10.1093/asj/sjag099

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。