文献速递乳房整形与再造

无菌与灭菌脱细胞真皮基质在放疗后乳房植入物重建中的安全性与组织学特征

Safety and histologic characteristics of aseptic and sterile acellular dermal matrices in irradiated implant-based breast reconstruction.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-05-08

本研究纳入157例(无菌型100例、灭菌型57例)接受两阶段植入物乳房重建并术后放疗的患者,比较两组并发症、BREAST-Q满意度及66例放疗后活检标本的组织学特征。中位随访39.8个月,两组感染、包膜挛缩及总体并发症无显著差异,满意度评分相当,ADM厚度及α-SMA、vimentin表达无差异,SEM显示灭菌型ADM放疗后胶原结构保留。结论认为两种加工方法在放疗背景下安全有效。

要点

  • 无菌与灭菌ADM在放疗后乳房重建中并发症和满意度相当
  • 两组ADM厚度及纤维化标志物α-SMA、vimentin表达无显著差异
  • 灭菌型ADM放疗后胶原超微结构保留,支持其临床适用性

核心结论

  • 无菌与灭菌ADM在放疗后植入物乳房重建中安全性、患者报告结局和组织学特征相当,两者均为安全有效的选择。

研究设计与样本

  • 回顾性比较研究,纳入2018至2022年接受两阶段植入物乳房重建并术后放疗的157例患者(无菌型100例、灭菌型57例)。
  • 分析术后并发症和BREAST-Q患者报告结局,对66例放疗后活检标本评估组织厚度及纤维化标志物,并行扫描电镜定性评估胶原超微结构。

主要发现

  • 平均随访39.8个月,两组术后感染、包膜挛缩及总体并发症发生率无显著差异。
  • BREAST-Q满意度、心理社会幸福感、性幸福感和身体健康评分两组相当。
  • 组织学分析显示两组ADM厚度无显著差异,α-SMA和vimentin表达无差异。
  • 定性SEM评估显示灭菌型ADM放疗后胶原架构保留。

临床怎么用

  • 在需术后放疗的植入物乳房重建中,无菌型与灭菌型ADM均可作为安全有效的选择,无需因放疗而偏好某一加工类型。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Acellular dermal matrices (ADMs) are widely used in implant-based breast reconstruction to enhance esthetic outcomes and reduce capsular contracture. However, concerns persist regarding their performance in patients undergoing postmastectomy radiation therapy (PMRT). The impact of ADM processing method-aseptic versus sterile-on clinical outcomes and postirradiation tissue characteristics remains incompletely defined. OBJECTIVES: To compare clinical outcomes, patient-reported satisfaction, and histologic characteristics of aseptic and sterile ADMs in implant-based breast reconstruction followed by PMRT. METHODS: This study included 157 patients (100 aseptic and 57 sterile) who underwent two-stage implant-based reconstruction with PMRT between 2018 and 2022. Postoperative complications and patient-reported outcomes (BREAST-Q) were analyzed. Postirradiation biopsy specimens from 66 patients were evaluated for tissue thickness and fibrosis-related markers (α-smooth muscle actin [α-SMA] and vimentin). Scanning electron microscopy was performed to qualitatively evaluate collagen ultrastructure following irradiation. RESULTS: During a mean follow-up of 39.8 months, no significant differences were observed between the groups in postoperative infection, capsular contracture, or overall complication rates. BREAST-Q scores for satisfaction, psychosocial well-being, sexual well-being, and physical well-being were comparable. Histologic analysis demonstrated no significant differences in ADM thickness. Expression of α-SMA and vimentin did not differ between the groups, indicating similar myofibroblast and fibroblast activity. Qualitative SEM assessment demonstrated preservation of collagen architecture in sterile ADM after irradiation. CONCLUSION: Aseptic and sterile ADMs demonstrated comparable safety profiles, patient-reported outcomes, and histologic characteristics in implant-based breast reconstruction with PMRT. Both ADM processing methods appear to be safe and effective options in the setting of PMRT.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Ha JH, Jin US. Safety and histologic characteristics of aseptic and sterile acellular dermal matrices in irradiated implant-based breast reconstruction. J Plast Reconstr Aesthet Surg. 2026. PMID: 42155419. doi:10.1016/j.bjps.2026.05.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。