增强活性脂肪移植用于乳房美容与再造的多中心前瞻性研究
这项14中心前瞻性研究纳入190例乳房脂肪移植患者(美容85例、再造105例),使用Viality系统联合AuraClens表面活性剂清洗处理脂肪。12个月平均保留率84.8%(95%CI 83.2–86.5),各时间点均显著高于70%历史基准(P<.0001),保留率受移植量、体重变化及移植/受区体积比影响。
要点
- Viality系统处理脂肪后12个月平均保留率84.8%,显著高于70%历史基准。
- 美容与再造队列保留趋势相似,早期即达稳态且无随时间显著变化。
- 移植体积、体重变化及移植/受区乳房体积比影响保留率。
核心结论
- Viality系统处理脂肪用于乳房美容与再造可获得早期稳态、持续高比例体积保留且结果一致,提示其为有效可预测的脂肪处理方式。
研究设计与样本
- 前瞻性14中心研究(NCT05258305),190例患者接受乳房脂肪移植,美容85例、再造105例,脂肪经Viality与AuraClens处理。
- 基于3D成像在基线及1、3、6、12个月行体积分析,评估12个月保留率及患者因素影响。
主要发现
- 平均保留率(95%CI):1个月86.6%(85.4–87.7),3个月83.1%(81.8–84.4),6个月84.1%(82.8–85.5),12个月84.8%(83.2–86.5)。
- 各时间点平均保留率均显著高于70%历史基准(P<.0001),保留率随时间无显著变化。
- 再造与美容队列趋势相似;保留率受脂肪移植量(P<.0001)、体重变化(P<.0001)及移植/受区乳房体积比(P=.0187)影响。
临床怎么用
- 可参考该处理系统用于乳房脂肪移植以提高并稳定体积保留,但需结合移植量、体重管理及受区体积比评估个体保留。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: . Autologous fat transfer (AFT) is a well-established technique for cosmetic breast augmentation and reconstructive breast procedures. Historically, however, graft retention has been highly variable. The Viality™ system (Tiger Aesthetics Medical, Conshohocken, PA) is an FDA-cleared, in-line fat processing device designed to concentrate viable adipocytes, improving retention. METHODS: . In this prospective, 14-center study (NCT05258305), 190 patients underwent AFT for cosmetic (n=85) or reconstructive (n=105) breast procedures. Harvested fat was processed with Viality and AuraClens™ surfactant wash. Volumetric analysis, based on 3D imaging, was performed at baseline and 1, 3, 6, and 12 months. Percentage retention and impact of patient factors on retention at 12 months were assessed. RESULTS: . Mean (95% CI) retention was 86.6% (85.4 to 87.7) at month 1, 83.1% (81.8 to 84.4) at month 3, 84.1% (82.8 to 85.5) at month 6, and 84.8% (83.2 to 86.5) at month 12. Mean retention was significantly greater at all timepoints than the historical benchmark of 70% (P <.0001) with no significant changes in retention over time. Similar trends were observed for reconstruction and cosmetic cohorts. Retention was affected by fat transfer volume (P<.0001), weight change (P<.0001), and graft-to-recipient breast volume ratio (P=.0187). CONCLUSIONS: . Early graft steady state, sustained high-percentage volume retention, and consistent results suggest that the Viality system is an effective, predictable modality for processing fat for cosmetic and reconstructive breast surgery, setting a new standard for sustained volume retention.
引用
- Shridharani SM, Eagan S, Tessler O, et al. A Multicenter Prospective Study of Enhanced Viability Fat Transfer for Cosmetic Augmentation and Reconstruction of the Breast. Plast Reconstr Surg. 2026. PMID: 42153746. doi:10.1097/PRS.0000000000013190
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。