文献速递乳房整形与再造美容整形

次氯酸冲洗预防初次假体隆乳包膜挛缩与感染

PhaseOne Hypochlorous Acid is Effective for Preventing Capsular Contracture and Infection in Primary Breast Augmentation.
PubMed 文献 · Aesthet Surg J · 2026-05-13

本研究回顾性比较初次假体隆乳术中四种冲洗液(0.025%次氯酸、抗生素联合聚维酮碘、单用抗生素、氯己定)的包膜挛缩与感染结局。共纳入243例患者(486侧乳房),平均随访13个月,次氯酸组包膜挛缩率0%、严重感染率1.2%、轻度感染率0%,与标准冲洗方案效果相当。

要点

  • 0.025%次氯酸冲洗组包膜挛缩率为0%,与氯己定组相同。
  • 次氯酸组严重感染率1.2%、轻度感染率0%,与其它冲洗液相近。
  • 作者认为次氯酸预防包膜挛缩与感染的效果不劣于标准冲洗技术。

核心结论

  • 与标准冲洗技术相比,PhaseOne 0.025%次氯酸在初次假体隆乳中预防包膜挛缩和感染同样有效。

研究设计与样本

  • 共243例患者(486侧乳房),平均随访13个月。
  • 比较四组冲洗液:次氯酸、抗生素联合聚维酮碘、单用抗生素、氯己定。

主要发现

  • 包膜挛缩率:次氯酸0%、抗生素联合聚维酮碘2.3%、单用抗生素1.7%、氯己定0%。
  • 严重感染率:次氯酸1.2%、抗生素联合聚维酮碘0.4%、单用抗生素0%、氯己定1.2%。
  • 轻度感染率:次氯酸0%、抗生素联合聚维酮碘0.5%、单用抗生素(不含聚维酮碘)1.7%、氯己定0%。

关键数值与推荐

  • 冲洗液浓度:0.025%次氯酸(HOCl)。
  • 研究关注结局为包膜挛缩、轻度感染(口服抗生素可缓解)和严重感染(需取出假体)。

临床怎么用

  • 初次假体隆乳术中可考虑使用0.025%次氯酸作为冲洗液之一,以预防包膜挛缩与感染。

局限性

  • 为回顾性研究,平均随访13个月,样本来自单一时段,未报告随机化与盲法信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Choice of breast pocket irrigation for implants remains highly contentious in the current literature. Several studies have demonstrated that 0.025% hypochlorous acid (HOCl) is highly effective for preventing infection and capsular contracture, without risk for cytotoxicity nor allergic reactions. This present study is the first to report outcomes of primary breast augmentation using HOCL irrigation. OBJECTIVES: To compare capsular contracture rates after primary breast augmentation of HOCL to alternative irrigation solutions. METHODS: A retrospective review was conducted on patients who underwent primary breast augmentation between January 2018 and December 2019. Four main groups of irrigation were compared: HOCL, antibiotic with povidone iodine (PI), antibiotic alone, chlorhexidine (CHG). Outcomes of interest were capsular contracture, mild infection (resolved with oral antibiotics), and severe infection (requiring explantation). RESULTS: A total of 243 patients (486 breasts) were included with an average follow-up of 13 months. Capsular contracture rates were as follows: 0% (HOCL), 2.3% (antibiotic solution with PI), 1.7% (antibiotic alone), and 0% (CHG). Severe infection rates were 1.2% (HOCl), 0.4% (antibiotic with PI), 0% (antibiotic alone), and 1.2% (CHG). Mild infection rates were 0% (HOCL), 0.5% (antibiotic with PI), 1.7% (antibiotic without PI), and 0% (CHG). CONCLUSIONS: Compared to standard irrigation techniques, PhaseOne 0.025% HOCL is equally effective in preventing capsular contracture and infection in primary breast augmentation.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Xia TY, Aminzada A, Nguyen D, et al. PhaseOne Hypochlorous Acid is Effective for Preventing Capsular Contracture and Infection in Primary Breast Augmentation. Aesthet Surg J. 2026. PMID: 42126291. doi:10.1093/asj/sjag094

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。