文献速递显微修复重建乳房整形与再造

术中动脉血栓时间分析:20分钟通畅检查的验证

Temporal analysis of intraoperative arterial thrombosis: Validation of a 20-min patency check.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-05-07

该回顾性研究分析2021至2025年438例患者454个显微动脉吻合,术中动脉血栓发生率为9.0%(41个吻合口),20分钟通畅检查敏感度78%、特异度98%,ROC分析提示57分钟为统计阈值(敏感度93%、特异度94%),非乳房再造中头颈再造血栓率10.8%,乳房再造无病例。

要点

  • 20分钟通畅检查敏感度78%、特异度98%,可有效检出术中动脉血栓。
  • 术中动脉血栓总发生率9.0%,头颈再造10.8%,乳房再造无血栓病例。
  • ROC提示57分钟阈值敏感度93%、特异度94%,关创前追加评估或可提高敏感度。

核心结论

  • 20分钟通畅检查对检出术中动脉血栓有效,尤其适用于非乳房再造;关创前追加评估可能有助于发现初次检查后形成的血栓。

研究设计与样本

  • 回顾性分析2021至2025年接受显微动脉吻合的438例患者共454个动脉吻合,主要结局为20分钟通畅检查的诊断准确性。

主要发现

  • 454个动脉吻合中41个(9.0%)发生术中动脉血栓,对应9.4%的患者。
  • 血栓均见于非乳房再造,头颈再造为10.8%,乳房再造无病例。
  • 41例血栓中78%在吻合完成后20分钟内检出。
  • 20分钟通畅检查敏感度78%、特异度98%。
  • ROC分析提示57分钟为统计阈值,敏感度93%、特异度94%;未发现与术中动脉血栓风险增加相关的患者因素。

关键数值与推荐

  • 20分钟通畅检查:敏感度78%,特异度98%。
  • ROC统计阈值57分钟:敏感度93%,特异度94%。
  • 术中动脉血栓发生率:41/454个吻合(9.0%),9.4%的患者。
  • 头颈再造术中动脉血栓率10.8%,乳房再造为0。
  • 41例血栓中78%在吻合完成后20分钟内检出。

临床怎么用

  • 常规20分钟通畅检查可用于术中动脉血栓筛查,非乳房再造尤其应重视。
  • 关创前可考虑追加通畅评估,以发现20分钟检查后延迟出现的血栓。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although most arterial thromboses occur within the first postoperative day, the precise timing of intraoperative arterial thrombosis remains poorly defined. We aimed to evaluate the accuracy of the 20-min patency check routinely performed at our institution and determine the optimal timing to detect intraoperative arterial thrombosis. METHODS: A retrospective analysis was conducted of patients who underwent microscopic arterial anastomosis between 2021 and 2025. The primary outcome was the diagnostic accuracy of the 20-min patency check. Secondary outcomes included the optimal timing for detecting intraoperative arterial thrombosis and patient-related factors associated with its occurrence. RESULTS: Among the 454 arterial anastomoses performed in 438 patients, intraoperative arterial thrombosis occurred in 41 anastomoses (9.0%), corresponding to 9.4% of patients. Thrombosis occurred in non-breast reconstructions, including 10.8% in head and neck reconstructions, whereas no cases were observed in breast reconstructions. Among the 41 thrombosis cases, 78% were detected within 20 min after anastomoses completion. The sensitivity and specificity of the 20-min patency check were 78% and 98%, respectively. Receiver operating characteristic analysis suggested a statistical threshold of 57 min for detecting intraoperative arterial thrombosis (sensitivity, 93%; specificity, 94%). No patient-related factors associated with an increased risk of intraoperative arterial thrombosis were identified. CONCLUSIONS: The 20-min patency check is effective for detecting intraoperative arterial thrombosis particularly in non-breast reconstructions. To further improve sensitivity, an additional assessment before wound closure may help identify thrombosis that developed after the initial check.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Katayama R, Araki J, Suzuki S, et al. Temporal analysis of intraoperative arterial thrombosis: Validation of a 20-min patency check. J Plast Reconstr Aesthet Surg. 2026. PMID: 42172926. doi:10.1016/j.bjps.2026.05.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。