象限算法在肿瘤整形乳房缩小术中的应用:镜像皮瓣填充上极肿块切除缺损
本研究回顾性分析2022年9月至2024年11月单术者47例(51侧乳房)肿瘤整形乳房缩小术病例,采用双组件镜像皮瓣技术重建上象限缺损。术后随访13.2±7.5个月,15.7%乳房发生并发症,1侧(2.0%)出现上极凹陷无需修整,6侧(11.8%)因并发症行修整。该算法可可靠重建上象限缺损,轮廓畸形率低。
要点
- 上外侧象限缺损占70.6%,上内侧象限占29.4%。
- 上外侧象限缺损采用上内侧蒂,上内侧缺损采用上外侧蒂。
- 所有上外侧象限缺损用下外侧推进皮瓣填充,上内侧缺损用下内侧皮瓣。
核心结论
- 双组件镜像皮瓣技术可可靠重建上象限缺损,轮廓畸形率低。
研究设计与样本
- 回顾性综述,单术者2022年9月至2024年11月行肿瘤整形乳房缩小术47例(51侧乳房)。
主要发现
- 肿瘤位于上外侧象限占70.6%,上内侧象限占29.4%。
- 随访13.2±7.5个月,15.7%乳房发生并发症。
- 1侧乳房(2.0%)出现上极凹陷,无需修整。
- 6侧乳房(11.8%)因并发症行修整,其中5/6与放疗相关,1/6与裂开相关。
关键数值与推荐
- 上外侧象限缺损采用上内侧蒂,上内侧缺损采用上外侧蒂。
- 上外侧象限缺损用下外侧推进皮瓣填充,上内侧缺损用下内侧皮瓣。
临床怎么用
- 对于上象限缺损的肿瘤整形乳房缩小术,可采用双组件镜像皮瓣算法进行重建。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Reconstructing upper-quadrant defects in oncoplastic breast reduction (OBR) can be challenging due to upper-pole concavity after tumor resection. To address this, we adopted a dual-component technique using 2 separate flaps: (1) a superiorly based flap for the nipple-areola complex (NAC) and (2) an inferior advancement flap from the quadrant ipsilateral to the lumpectomy defect, "mirroring" the laterality of the defect. This study evaluates outcomes using this algorithm for superior pole reconstruction in OBR. METHODS: A retrospective review was conducted of OBR cases performed by a single surgeon from September 2022 to November 2024. All were performed for oncologic indications and used an inferior flap for upper-quadrant volume displacement according to the senior author's algorithm demonstrated in Figure 1. RESULTS: A total of 47 patients (51 breasts) underwent lumpectomy and immediate OBR. Most tumors were located in the upper outer quadrant (UOQ; 70.6%), followed by the upper inner quadrant (UIQ; 29.4%). Superomedial NAC pedicles were used for UOQ defects, and superolateral pedicles for UIQ. All UOQ defects were filled with inferolateral advancement flaps, and all UIQ defects with inferomedial flaps. Over 13.2 ± 7.5 months of follow-up, 15.7% of breasts experienced complications. One breast (2.0%) had upper-pole concavity not requiring revision. Six breasts (11.8%) underwent revision secondary to complications related to radiation (5/6) or dehiscence (1/6). CONCLUSIONS: The proposed dual-component mirror flap technique reliably reconstructs superior quadrant defects with low rates of contour deformity.
引用
- Rohrich RN, Soltani H, Episalla NC, et al. A Quadrant-based Algorithm for Oncoplastic Breast Reduction: The Use of Mirror Flaps for Filling Superior Pole Lumpectomy Defects. Ann Plast Surg. 2026. PMID: 41811134. doi:10.1097/SAP.0000000000004700
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。