文献速递乳房整形与再造美容整形

自体脂肪移植乳房再造:三种脂肪处理技术的前瞻性随机对照试验中期分析

Clinical Outcomes Following Autologous Fat Grafting for Breast Reconstruction: An Interim Analysis From a Randomized Controlled Trial Comparing Lipoaspirate Processing Techniques.
PubMed 文献 · Ann Plast Surg · 2026-03-06

三组注射脂肪量无显著差异(P=0.33),3个月平均体积保留率分别为55.3%、58.7%和62.7%(P=0.52),AWFS数值最高但组间无统计学差异,提示三种处理技术长期结局相当。

要点

  • AWF、LPS与AWFS三组脂肪注射量及3个月体积保留率均无显著差异。
  • AWFS平均体积保留率62.7%为三组最高,但差异未达统计学意义。
  • 三种脂肪处理技术用于乳房再造的长期结局具有可比性。

核心结论

  • AWFS虽显示最高平均体积保留率,但三种处理技术间差异无统计学意义,长期结局相当。

研究设计与样本

  • 术前及术后3个月行上躯干三维扫描,以Autodesk Meshmixer测量乳房体积并计算体积保留率。
  • 组间体积保留率差异采用单因素方差分析。

主要发现

  • 注射脂肪量:AWF组89.0 ± 56.0 cm³,LPS组125.8 ± 68.9 cm³,AWFS组127.5 ± 78.7 cm³(P=0.33)。
  • 术后3个月平均体积保留率:AWF组55.3% ± 17.2%,LPS组58.7% ± 17.8%,AWFS组62.7% ± 15.7%。
  • 三组体积保留率差异无统计学意义(P=0.52)。

临床怎么用

  • 三种脂肪处理技术均可用于乳房再造脂肪移植,临床选择可综合考量操作便利性与资源条件。
  • AWFS虽数值上体积保留率最高,但现有证据尚不足以推荐其替代AWF或LPS。

局限性

  • 随访仅至术后3个月,缺乏更长期体积保留数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Autologous fat grafting (AFG) is commonly used in breast reconstruction for volume restoration or contour correction. Our previous study demonstrated that standard decantation yields inferior volume retention compared to active wash and filtration (AWF) and low-pressure decantation (LPS). Building upon these findings, we replaced standard decantation with a new processing technique, active wash with surfactant (AWFS). This study aims to evaluate long-term volume retention among AWF, LPS, and AWFS. METHODS: A prospective, randomized controlled trial was conducted at our institution between 2023 and 2025. Thirty patients were randomized in a 1:1:1 ratio to receive fat grafting processed by either AWF, LPS, or AWFS. Three-dimensional scans of the upper torso were obtained preoperatively and at 3 months postoperatively. Breast volume was measured using Autodesk Meshmixer, and volume retention was calculated as a percentage of the initial grafted volume. Differences in volume retention across groups were analyzed using one-way ANOVA. RESULTS: The volume of fat injected during the procedure did not differ significantly between groups: 89.0 ± 56.0 cm 3 for AWF, 125.8 ± 68.9 cm 3 for LPS, and 127.5 ± 78.7 cm 3 for AWFS ( P =0.33). Average volume retention at 3 months was 55.3% ± 17.2% for AWF, 58.7% ± 17.8% for LPS, and 62.7% ± 15.7% for AWFS. No significant difference in volume retention was observed across groups ( P =0.52). CONCLUSIONS: Although AWFS demonstrated the highest average volume retention, differences between techniques were not statistically significant. These findings suggest comparable long-term outcomes among the 3 processing methods.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Kochheiser M, Jalili P, Qin N, et al. Clinical Outcomes Following Autologous Fat Grafting for Breast Reconstruction: An Interim Analysis From a Randomized Controlled Trial Comparing Lipoaspirate Processing Techniques. Ann Plast Surg. 2026. PMID: 41811164. doi:10.1097/SAP.0000000000004701

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。