文献速递乳房整形与再造创面修复

革兰阴性菌感染与乳房植入物挽救率降低相关

The Association of Gram-Negative Bacteria With Decreased Salvage Rate in Infected Breast Implants.
PubMed 文献 · Ann Plast Surg · 2026-03-20

革兰阳性菌感染者挽救率为81.4%,革兰阴性菌感染者仅15.7%,差异有统计学意义(P<0.001)。革兰阴性菌感染更易在60天内导致植入物取出。

要点

  • 革兰阴性菌感染乳房植入物挽救率显著低于革兰阳性菌感染
  • 革兰阴性菌感染更易在60天内需取出植入物
  • 术中革兰染色或有助于指导感染处理决策

核心结论

  • 培养菌种类型与植入物挽救率明显相关,革兰阴性菌感染挽救率更低且更易在60天内取出植入物。

主要发现

  • 三组间差异经ANOVA检验有统计学意义,P值<0.001。

临床怎么用

  • 对植入物感染可考虑术中革兰染色早期识别革兰阴性菌,以指导是否取出植入物,避免延误辅助放化疗。

局限性

  • 原文未报告

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A total of 300,000 new cases of invasive breast cancer will be diagnosed in the United States this coming year accounting for >30% of all cancers diagnosed in women. Although breast-conserving surgery is on the rise, the number of BCS-eligible patients choosing mastectomy has increased and the number of breast reconstructions has increased 39% since 2000. The most common complication of implant-based reconstruction is infection. METHODS: This study utilized retrospective chart review of patients who underwent mastectomy with reconstruction requiring treatment of surgical site infection. Exclusion criteria included age younger than 18, delayed reconstruction, BMI >40, and perioperative chemoradiation. Statistical analysis was performed to test association between 2 dichotomous categorical variables: culture results and implant salvage rates. RESULTS: Eighty-seven patients met criteria, undergoing washout with fluid culture. Fifty-four grew Gram-positive, 44 resulted in salvage for a salvage rate of 81.4%. Nineteen grew Gram-negative, 3 resulted in salvage for a salvage rate of 15.7%. These results are statistically significant. Fourteen cultures showed no growth, all of which were salvaged. ANOVA showed statistically significant difference among the 3 groups with P -value <0.001. CONCLUSIONS: There's a clear correlation between type of bacteria cultured and salvage rates. Gram-negative infections are more likely to result in explantation within 60 days. This data may aid in the development of protocols utilizing intraoperative gram staining to guide management of these infections, ultimately helping with avoidance of additional operative procedures, which delay adjuvant chemoradiation.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Aiyash S, Campos A, Tiner C, et al. The Association of Gram-Negative Bacteria With Decreased Salvage Rate in Infected Breast Implants. Ann Plast Surg. 2026. PMID: 41855362. doi:10.1097/SAP.0000000000004723

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。