杂交DIEP联合假体乳房再造10年经验:皮瓣失败危险因素的单因素分析

10-Year Experience of Hybrid DIEP with Implant Breast Reconstruction: Univariate Analyses of Risk Factors Associated with Flap Failure.
PubMed 文献 · Plast Reconstr Surg · 2026-03-13

回顾性分析单术者2014—2024年91例(153侧)杂交DIEP联合假体乳房再造病例。初次植入后成功率为98%,假体更换后为96.1%。单因素分析显示,皮瓣失败组最终假体平均体积显著大于成功组,假体体积每增加50 mL的OR为1.42(95%CI:1.149-1.76,P=0.002)。

要点

  • 杂交DIEP联合假体乳房再造总体安全,初次植入成功率98%。
  • 较大体积假体与皮瓣失败相关,每增50 mL的OR为1.42。
  • 为升级而更换假体也存在皮瓣失败风险。

核心结论

  • 杂交DIEP联合假体乳房再造是安全术式。
  • 放置较大体积假体与皮瓣失败相关。
  • 为升级而更换假体也存在皮瓣失败风险。

研究设计与样本

  • 单中心、单术者回顾性综述,纳入2014—2024年接受杂交DIEP联合假体乳房再造的患者。
  • 共纳入91例患者、153侧乳房。
  • 分析患者特征与手术因素同皮瓣失败的关联。

主要发现

  • 初次(同期或延期)植入后成功率为98%。
  • 假体更换后成功率为96.1%。
  • 皮瓣失败组最终假体平均体积为362.50±228.05 mL,成功再造组为219.20±101.24 mL。
  • 假体体积每增加50 mL的OR为1.42(95%CI:1.149-1.76,P=0.002)。

临床怎么用

  • 术前规划假体体积时需权衡皮瓣失败风险,避免过大假体。
  • 假体更换升级操作应充分评估皮瓣失败风险。

局限性

  • 单术者、单中心回顾性研究,结果外推需谨慎。
  • 仅行单因素分析,未校正混杂因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The combination of deep inferior epigastric artery perforator (DIEP) free flap and implant has been reported as a safe option for breast reconstruction in patients with insufficient abdominal donor tissue. We present a single-surgeon 10-year experience with hybrid reconstruction. METHODS: We performed a retrospective review of patients who underwent hybrid breast reconstruction with DIEP and implant by a single surgeon at a single institution between 2014-2024. Patient characteristics and operative factors were analyzed for association with flap failure. RESULTS: 91 patients (153 breasts) were included. Success rate following initial (simultaneous or delayed) implantation and after implant exchange were 98% and 96.1%, respectively. Univariate analyses showed significantly larger mean final implant size in the failed DIEP group (362.50±228.05 mL) compared to the successful reconstruction group (219.20±101.24 mL), with OR of 1.42 (95% CI: 1.149-1.76, p-value = 0.002) per 50 mL increase of the implant size. CONCLUSIONS: Hybrid DIEP with implant reconstruction is a safe procedure. Placement of a greater volume implant is associated with flap failure. Implant exchange for upsize also possesses a risk of flap failure.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Lohasammakul S, D'John J, Qasawa R, et al. 10-Year Experience of Hybrid DIEP with Implant Breast Reconstruction: Univariate Analyses of Risk Factors Associated with Flap Failure. Plast Reconstr Surg. 2026. PMID: 41825067. doi:10.1097/PRS.0000000000013029