旋髂浅动脉穿支皮瓣静脉引流模式:手术规划与结局意义

Venous Drainage Pattern of Superficial Circumflex Iliac Artery Perforator (SCIP) Flap: Implications for Surgical Planning and Outcomes.
PubMed 文献 · Plast Reconstr Surg · 2026-03-26

该研究结合17具新鲜尸体和64例2019年9月至2021年2月行腹股沟皮瓣切取的患者,描述SCIP皮瓣静脉解剖与引流。尸体研究中30份标本有22份观察到SCIV及伴行静脉,临床研究出现2例皮瓣完全坏死和1例小血肿,无静脉淤血证据。结论将腹股沟皮瓣静脉引流分为不同类型,有助于手术规划。

要点

  • 尸体研究30份标本中22份观察到SCIV及伴行静脉。
  • 临床64例出现2例皮瓣完全坏死、1例小血肿,无静脉淤血。
  • SCIV按与伴行静脉连接方式分为两型,可指导SCIP皮瓣设计。

核心结论

  • 腹股沟皮瓣静脉引流模式可分类,有助于提高SCIP皮瓣手术精确性。
  • 理解SCIA与腹壁浅动脉系统之间的相互优势可提高腹股沟皮瓣可靠性。

研究设计与样本

  • 研究含尸体与临床两部分:尸体研究纳入17具新鲜尸体,排除既往腹股沟手术者。
  • 临床研究纳入2019年9月至2021年2月行腹股沟皮瓣切取的64例患者。
  • 证据等级为治疗性III级。

主要发现

  • 尸体研究中,30份标本有22份观察到SCIV及伴行静脉。
  • SCIV根据与伴行静脉的连接分为两型。
  • 临床研究出现2例皮瓣完全坏死和1例小血肿,无静脉淤血证据。

关键数值与推荐

  • 尸体研究将热盐水造影液注入股静脉以显示SCIP皮瓣静脉系统。
  • 临床术前采用CT血管造影和多普勒超声评估静脉模式,术中由资深外科医生记录。

临床怎么用

  • 术前可借助CT血管造影和多普勒超声评估SCIP皮瓣静脉模式以辅助规划。
  • 术中应关注SCIV与伴行静脉的连接类型及SCIA与腹壁浅动脉系统的相互优势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The superficial circumflex iliac artery (SCIA) perforator (SCIP) flap is widely used in reconstructive surgery due to its low donor site morbidity and favorable scar concealment. This research aims to describe the venous anatomy and drainage of the SCIP flap to enhance preoperative planning and improve surgical outcomes. METHODS: This investigation included both cadaveric and clinical studies. The cadaveric study involved 17 fresh cadavers, excluding those with prior groin surgery. Heated saline contrast solution was injected into the femoral vein to facilitate the visualization of the venous system of the SCIP flap. The clinical study involved 64 patients who underwent groin flap harvesting from September 2019 to February 2021. Preoperative venous patterns were assessed using computed tomography angiography and duplex ultrasound, while intraoperative findings were recorded by a senior surgeon. RESULTS: In the cadaveric study, the SCIV and accompanying venae comitantes (VC) were observed in 22 out of 30 specimens. The SCIV was classified into two types according to its connection with the VC. In the present clinical study, three perioperative complications were encountered, namely two total flap losses and one minor hematoma, with no evidence of venous congestion. CONCLUSIONS: The venous drainage patterns of the groin flap can be classified into distinct types, aiding surgeons in the planning and design of SCIP flaps to enhance surgical precision. Understanding the reciprocal dominance between SCIA and superficial inferior epigastric artery systems enhances the reliability of groin flaps, making them a versatile choice for reconstructive surgery.CLINICAL QUESTION / LEVEL OF EVIDENCE: Therapeutic, III.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Jeong HH, Tonaree W, Kang HI, et al. Venous Drainage Pattern of Superficial Circumflex Iliac Artery Perforator (SCIP) Flap: Implications for Surgical Planning and Outcomes. Plast Reconstr Surg. 2026. PMID: 41885534. doi:10.1097/PRS.0000000000013063

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。