文献速递乳房整形与再造显微修复重建

预测DIEP皮瓣重量的简单通用公式

Simple and generalizable formula for predicting deep inferior epigastric artery perforator flap weight in breast reconstruction.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2026-02-26

该研究回顾性分析100例DIEP皮瓣乳房再造患者,提出公式:预测皮瓣重量=α×W×H×T(W宽、H高、T皮下厚度、α设计特异系数)。WHT值与实际皮瓣重量Pearson相关系数0.964;5例、10例、20例估计系数时平均绝对百分比误差分别为12.7%、12.3%、12.2%。多因素分析显示皮下组织较薄显著增加估计误差(P=0.01)。

要点

  • 公式预测DIEP皮瓣重量与实际重量高度相关(r=0.964)。
  • 仅需少量病例估计系数α即可获得约12%的平均绝对百分比误差。
  • 皮下组织较薄者估计误差显著增大(P=0.01)。

核心结论

  • 该公式预测DIEP皮瓣重量准确性优良,仅需小样本简单测量即可推广用于术前规划。

主要发现

  • WHT值与实际皮瓣重量Pearson相关系数为0.964。
  • 使用5例、10例、20例估计系数时,平均绝对百分比误差分别为12.7%、12.3%、12.2%。
  • 多因素分析显示皮下组织较薄显著增加估计误差(P=0.01)。

关键数值与推荐

  • 预测皮瓣重量=α×W×H×T,其中W为皮瓣宽度、H为高度、T为皮下厚度、α为每种皮瓣设计特异系数。

临床怎么用

  • 术前可用该公式结合皮瓣宽、高及皮下厚度预测DIEP皮瓣重量,辅助手术规划以减少供区并发症和灌注相关问题。

局限性

  • 原文未报告具体局限性内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Prediction of flap weight is valuable for surgical planning when using a deep inferior epigastric artery perforator (DIEP) flap for breast reconstruction and may reduce donor site morbidity and perfusion-related problems. The aim of this research was to develop a simple and generalizable formula for predicting DIEP flap weight. METHODS: We retrospectively reviewed 100 patients who underwent breast reconstruction with a DIEP flap at our institution between November 2018 and July 2025. We developed the following formula: predicted flap weight = α × W × H × T, where W and H denote flap width and height, T denotes subcutaneous thickness, and α is a coefficient specific to each flap design. The relationship between the WHT value and actual flap weight was assessed using the Pearson correlation coefficient. Prediction accuracy was evaluated by K-fold cross-validation. The number of folds was varied to examine the relationship between the number of training cases and prediction accuracy. Multivariate analysis was performed to identify factors associated with estimation error. RESULTS: The Pearson correlation coefficient was 0.964. The mean absolute percentage error was 12.7% when using 5 cases to estimate the coefficient, 12.3% when using 10 cases, and 12.2% when using 20 cases. Multivariate analysis revealed that thinner subcutaneous tissue significantly increased the estimation error (P = 0.01). CONCLUSIONS: This formula demonstrated excellent accuracy, requiring only a simple measurement in a small sample. This approach is practical and generalizable for preoperative planning of breast reconstruction using a DIEP flap and is broadly applicable across institutions and flap designs.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Suzuki S, Goto D, Azuma S, et al. Simple and generalizable formula for predicting deep inferior epigastric artery perforator flap weight in breast reconstruction. J Plast Reconstr Aesthet Surg. 2026. PMID: 41831266. doi:10.1016/j.bjps.2026.02.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。