重建手术中ICG-FA主观判读:感知与灌注的差异
本研究评估了重建手术中吲哚菁绿荧光血管造影(ICG-FA)判读者间差异及其预测灌注相关并发症的能力。
要点
- ICG-FA主观判读的观察者间一致性仅为中等(κ=0.42)。
- 对存在灌注相关并发症的皮瓣,判读正确率显著降低(OR 0.04)。
- 判读准确性不受经验水平(住院医师 vs 顾问医师)显著影响。
核心结论
- ICG-FA主观判读存在显著的观察者间差异,视觉识别静脉流出障碍和细微灌注异常较为困难,定量ICG-FA可能有助于解决这些局限。
研究设计与样本
- 来自阿姆斯特丹UMC整形、重建与手外科的顾问医师和住院医师对30个重建病例的ICG-FA视频进行判读,将灌注分类为正常、可疑或受损。
主要发现
- 与无并发症皮瓣相比,判读者对存在灌注相关并发症的皮瓣使用ICG-FA正确评估灌注的可能性显著更低(OR 0.04,95%CI 0.003-0.41,p=0.007)。
- 观察者经验(住院医师 vs 顾问医师)对评估准确性无显著影响(OR 1.08,95%CI 0.52-2.23,p=0.83)。
关键数值与推荐
- 总体观察者间一致性Fleiss Kappa为0.42,住院医师为0.44,顾问医师为0.35。
- 灌注相关并发症皮瓣正确判读的OR为0.04(95%CI 0.003-0.41,p=0.007)。
- 经验水平对判读准确性的OR为1.08(95%CI 0.52-2.23,p=0.83)。
临床怎么用
- 临床使用ICG-FA判读皮瓣灌注时需警惕主观差异,尤其对疑似静脉流出障碍或细微灌注异常应结合其他监测手段。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Indocyanine green fluorescence angiography (ICG-FA) enables real-time visualization of perfusion in reconstructive surgery. However, interpretation remains largely subjective and may be influenced by multiple factors. This study aimed to evaluate interobserver variability in ICG-FA interpretation and its ability to predict perfusion-related complications. METHODS: Consultants and residents from the Department of Plastic, Reconstructive and Hand Surgery at Amsterdam UMC assessed 30 ICG-FA videos of reconstructive cases, classifying perfusion as normal, suspicious, or compromised. Interobserver agreement was analyzed using Fleiss' Kappa. A generalized linear mixed model (GLMM) was used to evaluate the effect of experience level and the presence of a perfusion-related complication on assessment accuracy. RESULTS: Fifteen participants completed the survey (eight residents, seven consultants). Overall agreement was moderate (κ = 0.42), slightly higher among residents (κ = 0.44) than consultants (κ = 0.35). Observers were significantly less likely to correctly assess flap perfusion using ICG-FA in flaps with a perfusion-related complication compared with uncomplicated flaps (OR 0.04, 95% CI 0.003-0.41, p = 0.007). Observer experience (resident vs. consultant) did not significantly influence assessment accuracy (OR 1.08, 95% CI 0.52-2.23, p = 0.83). CONCLUSION: These findings demonstrate substantial interobserver variability in subjective ICG-FA interpretation and highlight the difficulty of visually identifying venous outflow disturbances and subtle perfusion abnormalities. Quantitative ICG-FA may help address these limitations.
引用
- van 't Hof LWP, Weck AEMM, Damsgaard TE, et al. Subjective interpretation of ICG-FA in reconstructive surgery: Perception versus perfusion. J Plast Reconstr Aesthet Surg. 2026. PMID: 41791200. doi:10.1016/j.bjps.2026.02.044
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。