文献速递烧伤创面修复

吲哚菁绿评估烧伤深度:宏观可视化与微环境间的差异

Evaluation of Burn Depth using Indocyanine Green: Discrepancies Between Macroscopic Visualization and the Microenvironment.
PubMed 文献 · Plast Reconstr Surg · 2026-03-10

本研究纳入14例深度不确定或深二度烧伤患者,于伤后2-3天或术前注射吲哚菁绿,行血管造影和次日第二窗口ICG成像,并取全层活检行组织学评估。体外培养人成纤维细胞和角质形成细胞热损伤后与ICG孵育,用流式细胞术分类并量化摄取。结果表明ICGA灌注参数在无需植皮创面升高,SWIG荧光强度与组织学深度相关并定位于坏死区,但患者间变异大。

要点

  • ICGA灌注参数在无需植皮的烧伤创面中升高。
  • SWIG荧光强度与组织学烧伤深度相关,定位于坏死区。
  • SWIG荧光强度与组织学深度、预测愈合潜力及植皮状态间患者间变异大。

核心结论

  • 荧光成像有潜力辅助评估烧伤愈合潜力,但成像变异、解读和临床整合等挑战需解决。

研究设计与样本

  • 纳入14例深度不确定或深二度烧伤患者,伤后2-3天或术前注射ICG,行ICGA和次日SWIG成像,取全层活检行组织学评估。
  • 体外培养人成纤维细胞和角质形成细胞,65℃热损伤2.5或5分钟后与ICG孵育,流式细胞术分类活、凋亡、坏死细胞并量化ICG摄取。

主要发现

  • ICGA灌注参数在无需植皮的烧伤创面中升高。
  • ICGA流出斜率与SWIG荧光强度相关。
  • SWIG显微荧光强度与组织学烧伤深度相关,并共定位于坏死区。
  • SWIG荧光强度与组织学深度、预测愈合潜力及植皮状态间患者间变异大。
  • 体外流式分析显示ICG优先结合坏死细胞,结合受细胞类型和损伤严重程度影响。

临床怎么用

  • ICG荧光成像可能辅助评估烧伤愈合潜力,但当前成像变异和解读挑战需解决后方可优化临床应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Burn wound management is guided by the depth of dermal tissue damage. Standard practice for this depth assessment is daily visual evaluation of the wound by an experienced burn surgeon, which is inherently subjective and at times inaccurate. Perioperative fluorescence imaging with indocyanine green (ICG) has emerged as a potential tool to objectively evaluate burn depth. The current study aims to explore the relationship between ICG angiography (ICGA), Second-window ICG (SWIG), and burn depth, with the goal of understanding how this technology could guide the prognosis and treatment of human burn wounds. METHODS: Patients (n = 14) with indeterminate depth or deep partial thickness burns received an infusion of ICG on post-burn day 2-3 or the day before surgery. Imaging was performed immediately after injection for angiography as well as the following day for SWIG. A full-thickness tissue biopsy was obtained for histologic evaluation. In vitro primary human fibroblasts and keratinocytes were cultured, subjected to heat injury (65 deg C for 2.5 or 5 minutes), and incubated with ICG. Flow cytometry was used to classify the cells as live, apoptotic, or necrotic based and to quantify ICG uptake. RESULTS: ICGA perfusion parameters are increased in burn wounds that did not require grafting and ICGA egress slope correlates to SWIG fluorescence intensity. Furthermore, SWIG microscopic fluorescence intensity correlates to histologic burn depth and colocalizes in necrotic region of burn injury, however there is high interpatient variability between SWIG fluorescence intensity and histologic burn depth, predicted healing potential, and graft status. Flow cytometric analysis of in vitro skin cells shows that preferential ICG binding to necrotic cells contributes to SWIG signal in a burn, with binding influenced by cell type and injury severity. CONCLUSIONS: Overall, this study suggests that fluorescence imaging has the potential to aid in the assessment of healing potential, although current challenges related to imaging variability, interpretation, and clinical integration must be addressed to optimize its utility in burn management.Clinical trials number: NCT05593523.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Junak M, García H, Liu A, et al. Evaluation of Burn Depth using Indocyanine Green: Discrepancies Between Macroscopic Visualization and the Microenvironment. Plast Reconstr Surg. 2026. PMID: 41805739. doi:10.1097/PRS.0000000000013011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。