机器人显微外科在游离皮瓣重建中的有效性与安全性:系统综述与单臂荟萃分析
汇总分析显示皮瓣存活率达96%(95%CI 93-98%),平均吻合时间39.1分钟(95%CI 33.0-45.1),提示机器人显微吻合在解剖受限术野中临床可行、安全且高效。
要点
- 机器人显微吻合皮瓣存活率96%(95%CI 93-98%),平均吻合时间39.1分钟(95%CI 33.0-45.1)
- SYMANI系统使用212例(80%),da Vinci系统54例(20%),重建多涉及颅颌面及头颈区域
- 338个机器人吻合中动脉占67%、静脉占33%,端端吻合70%、端侧吻合30%
核心结论
- 机器人辅助微血管吻合临床可行、安全且高效,尤其在解剖受限术野中。
- 尚需对照研究与长期研究明确其相对于传统显微技术的定位。
研究设计与样本
- 系统综述与单臂荟萃分析,遵循PRISMA指南,检索PubMed、Embase和Web of Science。
主要发现
- 机器人系统以SYMANI为主用于212例(80%),da Vinci用于54例(20%)。
- 重建最常涉及颅颌面及头颈区域,常用游离皮瓣包括桡前臂、股前外侧、游离腓骨和尺前臂皮瓣。
- 338个机器人吻合中动脉占67%、静脉占33%,端端吻合70%、端侧吻合30%。
- 汇总皮瓣存活率96%(95%CI 93-98%),平均吻合时间39.1分钟(95%CI 33.0-45.1)。
临床怎么用
- 在解剖受限术野的游离皮瓣重建中可考虑机器人辅助微血管吻合。
- 需结合本中心机器人系统可及性与术者培训情况个体化选择。
局限性
- 纳入研究均为单臂设计,缺乏与传统显微技术的直接对照。
- 缺乏长期随访数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Robotic microsurgery has emerged as a promising advancement in plastic and reconstructive surgery, offering enhanced precision through tremor suppression and motion scaling during microvascular anastomosis. This systematic review and single-arm meta-analysis synthesizes contemporary clinical evidence on the safety, feasibility, and operative performance of robotic-assisted microvascular reconstruction. Literature searches were performed in PubMed, Embase, and Web of Science. Thirteen clinical studies involving 264 patients were included in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Robotic systems used were predominantly the SYMANI® Surgical System (Medical Micro Instruments S.p.A., Pisa, Italy), utilized in 212 patients (80%), followed by the da Vinci® Surgical System (Intuitive Surgical, Inc., Sunnyvale, California, USA), used in 54 patients (20%). Reconstructions most commonly involved the cranio-maxillofacial and head and neck regions. Across 338 robotic anastomoses, 67% were arterial and 33% venous, performed using either end-to-end (70%) or end-to-side (30%) techniques. Common free flaps included radial forearm, anterolateral thigh, free fibula, and ulnar forearm flaps. Pooled analysis demonstrated a high flap survival rate of 96% (95% CI 93-98%) and a mean anastomosis time of 39.1 min (95% CI 33.0-45.1). These findings indicate that robotic-assisted microsurgical anastomosis is clinically feasible, safe, and efficient, particularly in anatomically constrained operative fields. Further comparative and long-term studies are required to define its role relative to conventional microsurgical techniques.
引用
- Sudarman JP, Triatmoko SE, Siburian ES, et al. Effectiveness and safety of robotic microsurgery in free-flap reconstruction: A systematic review and single-arm meta-analysis. J Plast Reconstr Aesthet Surg. 2026. PMID: 41722469. doi:10.1016/j.bjps.2026.02.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。