文献速递显微修复重建创面修复

穿支螺旋桨皮瓣修复小腿远端、踝部及后足的设计优化:系统综述与荟萃分析

"Optimizing Perforator-Based Propeller Flap Design for Distal Leg, Ankle and Hindfoot Reconstruction: A Systematic Review and Meta-Analysis".
PubMed 文献 · Plast Reconstr Surg · 2026-02-26

该系统综述与个体患者数据荟萃分析纳入27项研究共402个穿支螺旋桨皮瓣,评估设计参数对并发症的影响。靶部位并发症发生率为22%(95%CI:17%-27%),总皮瓣坏死率低(2%)。皮瓣宽度>4.5 cm、面积40-80 cm²及皮瓣-缺损比<2.5与较低并发症相关,支持其作为小腿远端缺损的单期修复选择。

要点

  • 穿支螺旋桨皮瓣总坏死率仅2%,多数部分坏死经植皮闭合。
  • 皮瓣宽度>4.5 cm、面积40-80 cm²与较低并发症相关。
  • 皮瓣-缺损比<2.5与较低并发症相关(P=0.15)。

核心结论

  • 穿支螺旋桨皮瓣总坏死率低(2%),多数部分坏死经植皮闭合。
  • 保持皮瓣面积40-80 cm²、宽度>4.5 cm、皮瓣-缺损比<2.5可获得最佳结局。
  • 穿支螺旋桨皮瓣是小腿远端缺损可靠的单期游离皮瓣替代方案。

研究设计与样本

  • 系统综述与个体患者数据荟萃分析,检索PubMed、Embase和Cochrane Library截至2025年3月。
  • 共纳入27项研究的402个穿支螺旋桨皮瓣。
  • 主要结局为靶部位并发症、血管并发症和皮瓣坏死,并评估穿支位置、皮瓣宽度、面积和旋转弧度等设计参数的影响。

主要发现

  • 402个皮瓣中靶部位并发症发生率为22%(95%CI:17%-27%)。
  • 静脉淤血发生率为4%,皮瓣坏死发生率为12%。
  • 皮瓣宽度>4.5 cm时并发症发生率为22%(P=0.02)。
  • 皮瓣面积40-80 cm²时并发症发生率为18%(P=0.04)。
  • 皮瓣-缺损比<2.5时并发症发生率为16%(P=0.15)。

关键数值与推荐

  • 推荐皮瓣宽度>4.5 cm(并发症22%,P=0.02)。
  • 推荐皮瓣面积40-80 cm²(并发症18%,P=0.04)。
  • 推荐皮瓣-缺损比<2.5(并发症16%,P=0.15)。

临床怎么用

  • 设计穿支螺旋桨皮瓣时优先将宽度控制在>4.5 cm。
  • 将皮瓣面积控制在40-80 cm²以降低并发症风险。
  • 保持皮瓣-缺损比<2.5,并可用于小腿远端缺损的单期修复。

局限性

  • 证据等级为治疗性III级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Perforator-based propeller flaps (PPF) have emerged as an important reconstructive option for distal lower-extremity defects. While previous studies have reported outcomes, the optimal design parameters and their impact on complications remain unclear. This study aimed to establish evidence-based guidelines for PPF design through a systematic review and meta-analysis of individual patient data. METHODS: PubMed, Embase, and Cochrane Library were searched for studies published through March 2025. A total of 402 propeller flaps from 27 studies were included in the meta-analysis. Primary outcomes included target site complications (TSC), vascular complications, and flap necrosis. Design parameters, including perforator location, flap width, flap dimension, and rotational arc, were evaluated for their impact on outcomes. RESULTS: Among 402 flaps, TSC occurred in 22% (95% CI: 17%-27%), including venous congestion (4%) and flap necrosis (12%). Lower complication rates were associated with flap width >4.5 cm (22%; P = 0.02), flap dimension 40-80 cm² (18%; P = 0.04), and flap-to-defect ratio <2.5 (16%; P = 0.15). CONCLUSION: PPF show a low total flap necrosis rate (2%), with most partial losses closed by skin grafting. Keeping flap dimension within 40-80 cm², width > 4.5 cm, and flap-to-defect ratio < 2.5 preserves optimal outcomes, confirming PPF as dependable single-stage alternatives to free flaps for distal lower-extremity defects.Clinical Question/Level of Evidence: Therapeutic, Level III.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Huang SC, Yeh YS, Chen WH, et al. "Optimizing Perforator-Based Propeller Flap Design for Distal Leg, Ankle and Hindfoot Reconstruction: A Systematic Review and Meta-Analysis". Plast Reconstr Surg. 2026. PMID: 41758125. doi:10.1097/PRS.0000000000012993

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。