吲哚菁绿血管造影预测DIEP皮瓣乳房再造术后体积变化
该回顾性队列纳入44例单侧单蒂DIEP皮瓣乳房再造患者,术中行ICG血管造影计算ICG流入比例,术后约1年用MRI测体积。1年平均皮瓣体积为初始85.2%,ICG流入比例越高体积保留越好(β=0.083,P=0.047),放疗与体积丢失增加相关(β=-0.155,P<0.001),预测高于平均体积保留的最佳截断值为1.325(AUC=0.700)。
要点
- ICG流入比例越高,DIEP皮瓣1年体积保留越好
- 放疗与术后皮瓣体积丢失增加独立相关
- 预测高于平均体积保留的ICG流入比例截断值为1.325
核心结论
- 术中ICG血管造影可指导DIEP皮瓣乳房再造的术中决策以优化术后体积结局。
- 较高的术中ICG流入比例预测更好的长期体积保留。
研究设计与样本
- 回顾性队列研究,纳入2019年9月至2024年2月44例单侧单蒂DIEP皮瓣乳房再造患者。
- 术中ICG血管造影评估皮瓣灌注并计算ICG流入比例,术中及术后约1年用MRI测皮瓣体积。
- 采用多变量线性回归和受试者工作特征分析识别体积保留的预测因素。
主要发现
- 术后1年平均皮瓣体积为初始体积的85.2%。
- 较高的ICG流入比例与更好的体积保留显著相关(β=0.083;P=0.047)。
- 放疗与体积丢失增加相关(β=-0.155;P<0.001)。
- 预测高于平均体积保留的最佳ICG流入比例截断值为1.325(AUC=0.700)。
关键数值与推荐
- ICG流入比例预测高于平均体积保留的截断值为1.325(AUC=0.700)。
- 术后1年平均皮瓣体积为初始体积的85.2%。
临床怎么用
- 术中可参考ICG流入比例指导皮瓣设计与决策,目标比例高于1.325可能支持更好的对称性。
- 对接受放疗的患者应更谨慎评估皮瓣体积保留。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Deep inferior epigastric artery perforator (DIEP) flaps are commonly used in breast reconstruction due to their muscle-sparing nature. However, postoperative volume changes can affect long-term breast symmetry. This study evaluates the predictive value of intraoperative indocyanine green (ICG) angiography findings for postoperative volume changes in DIEP flaps. METHODS: This retrospective cohort study included 44 patients who underwent unilateral breast reconstruction with unipedicled DIEP flaps between September of 2019 and February of 2024. Intraoperative flap perfusion was assessed using ICG angiography, and the ICG flow inset ratio was calculated. Flap volume was measured intraoperatively and about 1 year postoperatively using magnetic resonance imaging. Multivariable linear regression and receiver operating characteristic analysis were performed to identify predictors of volume preservation. RESULTS: The average flap volume at 1 year was 85.2% of the initial volume. Higher ICG flow inset ratios were significantly associated with better volume preservation (β = 0.083; P = 0.047); radiotherapy was correlated with increased volume loss (β = -0.155; P < 0.001). The optimal ICG flow inset ratio cutoff for predicting above-average volume maintenance was 1.325 (area under the receiver operating characteristic curve = 0.700). CONCLUSIONS: ICG angiography can guide intraoperative decision-making to optimize postoperative volume outcomes in breast reconstruction. Higher intraoperative ICG flow inset ratios predict improved long-term volume preservation in DIEP flap breast reconstruction. Targeting a ratio above 1.325 and careful flap design may support better symmetry, particularly in patients undergoing radiotherapy.
引用
- Kim J, Kim B, Jun D, et al. Indocyanine Green Angiography Predicts Postoperative Volume Changes in DIEP Flap Breast Reconstruction. Plast Reconstr Surg. 2025. PMID: 41453298. doi:10.1097/PRS.0000000000012776
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。